Technical Information
CVA4070 / CVA4075 Coffee Systems
Position
Display /
Activation
Description / Results
Open
The solenoid for hot water is
opened.
COMPONENT
TEST
HOT WATER
VALVE
Close
The solenoid for hot water is
closed.
initialize
The micro switches are tested,
and the brew unit is returned to
its home position. To prevent
mechanical damage, as a final
step, always activate intializing.
move clockwise for given period
of time
move counter-
clockwise for given
period of time
move counter-
clockwise for given
period of time
The brew unit moves into the
respective direction.
home position(1)
drain position (1)
COMPONENT
TEST
BREW UNIT
compressing
position (1)
The brew unit moves into the
respective direction.
On
The grinder is running.
COMPONENT
TEST
GRINDER
Off
The grinder is switched off.
On
The pump coffee/hot water
runs.
COMPONENT
TEST
WATER
PUMP
Off
The pump coffee/hot water is
switched off.
On
The steam pump runs.
COMPONENT
TEST
STEAM
PUMP
Off
The steam pump is switched
off.
On
The coffee/hot water and the
steam pumps operate until both,
the coffee/hot water and steam
system.
COMPONENT
TEST
SYSTEM
DRAIN
PUMP
Off
The coffee/hot water and the
steam pumps are switched off.
Table 6-9:
CVA4070 Service Mode (Cont. from Table 6-8; Cont. on Table 6-10)