Converting to another gas type
*INSTALLATION*
61
Checking the first intake of air
a
Adjustment screw
b
Air intake sleeve
Gap X
must
measure:
For natural gas: 6 mm
For liquid gas: 13 mm
To set gap X
Loosen screw
and slide the air in-
take sleeve
.
Then retighten the screw.
Changing the small jet
a
Small diameter jet
(e.g. for liquid gas: 0,23)
b
Large diameter jet
(e.g. for liquid gas: 0,60)
Using a small screwdriver, unscrew
the two small jets
and
in the gas
fitting.
Pull out the jets with a pair of pliers.
Fit the new jets securely (see jet ta-
ble).
Secure the jets against inadvertent
loosening with sealing wax.