Program settings
111
Setting the wash
block tempera-
ture
The wash block temperature is reached by heating up the chamber
wash solution. The temperature must be suited to the requirements of
the task.
At temperatures over 131°F (55°C), protein denaturing occurs,
which can cause the soiling to fix.
...
Wash block temperature
Wash block temp.
Set
Without heater
-
Without heater
The chamber wash solution is not heated up. The temperature in
the wash cabinet is the result of the temperature of the previous
wash block and the influx of water.
-
Set
Set a wash block temperature.
Select an option using the
and
arrow buttons.
Press
OK
to save the setting.
When
Set
is selected, the wash block temperature must then be en-
tered.
Wash block temp.
60
(30 - 93
°C
°C)
Adjustment is in increments of 1. The possible range is shown in the
bottom line.
Dispensing of process chemicals occurs at a default dispensing tem-
perature set at the factory. If process chemicals are to be dispensed
in this wash block, the lowest temperature that can be set will be the
dispensing temperature. It is not possible to set a lower value.
Use the arrow buttons
(higher) and
(lower) to set the wash
block temperature.
Press
OK
to save the setting.