background image

Midtronics Inc.     7000 Monroe Street     Willowbrook, IL 60527

www.midtronics.com

5

1: Introduction

JDT-1

Personal Precautions

Risk of explosive gases. 

Never smoke or allow a spark or 

flame in the vicinity of a battery.

Batteries can produce a highly explosive mix 

of hydrogen gas and oxygen, even when the 

battery is not in operation. Always work in a 

well-ventilated area.

Wash hands after handling.

REQUIRED BY CALIFORNIA PROP. 65: Battery posts, 

terminals, and related accessories contain lead and lead 

compounds, chemicals known to the state of California to 

cause cancer and birth defects or other reproductive harm.

Inspect the battery for damage and check the electrolyte level. 

If the electrolyte level is too low, replenish it and fully charge 

the battery. Always use the necessary safety precautions when 

working with batteries to prevent severe injury or death. 

Follow all manufacturers’ instructions and BCI (Battery Council 

International) safety recommendations, which include the 

following precautions:

 

Battery acid is highly corrosive. If acid enters your eyes, 

immediately flush them thoroughly with cold running 

water for at least 15 minutes and seek medical attention. 

If battery acid gets on your skin or clothing, wash imme-

diately with a mixture of water and baking soda.

 

Always wear proper safety glasses or face shield when 

working with or around batteries.

 

Keep hair, hands, and clothing as well as the analyzer 

cords and cables away from moving engine parts.

 

Remove any jewelry or watches before you start servicing 

the battery.

 

Use caution when working with metallic tools to prevent 

sparks or short circuits.

 

Never lean over a battery when testing, charging, or jump 

starting.

Symbols Conventions

Symbol

Description

!

The safety symbol indicates instructions for 

avoiding hazardous conditions and personal injury.

The safety symbol with the words 

CAUTION

WARNING, or DANGER

 indicates instructions for 

avoiding hazardous conditions and personal injury.
The wrench symbol indicates procedural notes and 

helpful information.

Description

The analyzer uses function-specific applications accessed 

through a series of menus and icons to guide users through the 

battery testing process for consistent testing implementation 

and accuracy.  These are accessed using the tester’s touch 

screen display.  Test results can be displayed on the full-color 

screen, printed, or wirelessly emailed.

Accessories

A033 Lead Post Adapters

Tester Components

 

Carrying Handle

 

Charging LED / Display 

Light Sensor

 

Power Button

: Hold for 

2 seconds to turn the 

tester on and off.

 

Touch Screen: Primary 

user interface. Startup 

screen displayed.

 

  Temperature Sensor: For measuring battery temperature.

  Camera & Flashlight: For VIN scanning and identification.

1: Introduction

Summary of Contents for JDT-1 WM

Page 1: ...Users Guide November 2019 167 000938EN A JDT 1 WM Battery Diagnostic Service System For testing 6 and 12 volt automotive 12 volt and 24 volt charging systems For Technical Support call 866 592 8052...

Page 2: ......

Page 3: ...12 Totals By Test Type 12 Totals By Date And Location 12 Vehicle History 12 Vehicle Select Option 12 6 Messages 13 Accessing Messages 13 Message Types 13 7 Settings 14 WiFi 14 Adding A Network 14 Dele...

Page 4: ......

Page 5: ...ing soda Always wear proper safety glasses or face shield when working with or around batteries Keep hair hands and clothing as well as the analyzer cords and cables away from moving engine parts Remo...

Page 6: ...ectrolyte level is too low add distilled water to fill up to above the top of the plates and fully charge the battery Do not overfill Corroded or loose battery tray and hold down fixture Tighten or re...

Page 7: ...i successfully connnected screen 4 Select Time Zone 5 Select the correct Date Time 6 Select the correct Walmart store from the displayed list 7 Confirm the store information is correct and tap Next 8...

Page 8: ...ecommended scanning procedures and VIN scanning help Manual Entry Use the on screen keypad to manually type the 17 digit VIN and tap Next 1 2 3 4 5 6 7 8 9 0 W E R T Y U P A S D F G H J K L Z X C V B...

Page 9: ...ible test results System Test 1 Tap to proceed with the System Test 2 Start the engine and let it idle 3 Tap Next The analyzer tests the alternator output 4 When prompted rev the engine to between 200...

Page 10: ...hicle Year Test Location Vehicle Make Rating Units Vehicle Model Battery Rating Vehicle Technology Battery Installation 4 Use the Viewing Window to align the temperature sensor over the battery and ta...

Page 11: ...g lists to select the year make and vehicle model If applicable a list of optional original equipment is displayed Use Manual Entry if the battery being tested is not listed Tap to continue to the Edi...

Page 12: ...en Weld Replace Charge Retest Temp Sensor Failed Replace Battery Aborted Badcell Short Replace Invalid Test Totals By Test Type Displays test totals by test type In Vehicle Test After New Battery Inst...

Page 13: ...to the Main Menu Accessing Messages A number is displayed next to the Messages icon when the analyzer has received any critical messages The number does not include non critical Notifications Unread C...

Page 14: ...Displays all entered email addresses Addresses can be added edited and deleted Admin Only Entered email accounts are added to the email address book Frequently used email addresses can be selected fro...

Page 15: ...time before the tester goes into a power saving Sleep mode Default 2 minutes Dim Time Adjust the amount of elapsed time before the tester goes into a power saving Dim mode Default 1 minute BMIS Entera...

Page 16: ...parators Create MDCA Log File The MDCA function is used by Midtronics technical support 2 Tap to return to the Shop Information screen Accessories Displays connected and linked accessory devices Addit...

Page 17: ...soline Electric Start Stop Hybrid Start Stop Diesel Battery Installation Single Battery or Dual Batteries Battery Application Automotive Marine Powersport Group 31 Commercial 4D 8D Lawn and Garden Bat...

Page 18: ...ery shows good cranking performance but low charge and low reserve capacity performance Low reserve capacity will compromise the battery s ability to provide power to the vehicle and hold a charge ove...

Page 19: ...eplace if necessary and retest If the belts and connections are in good working condition replace alternator or external voltage regulator LOW OUTPUT Alternator not providing enough current to power e...

Page 20: ...r left portion on the back of the Controller handle Flashlight Camera Hold Steady Hold Controller steady when scanning the VIN barcode This allows the user to clearly see the bar code and allows the c...

Page 21: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 21 Appendix C Recommended Test Procedure JDT 1...

Page 22: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 22 Appendix C Recommended Test Procedure JDT 1...

Page 23: ...Midtronics Inc 7000 Monroe Street Willowbrook IL 60527 www midtronics com 23 Appendix C Recommended Test Procedure JDT 1...

Page 24: ...anadian Inquiries TollFree 118665928052 Midtronics b v European Headquarters Houten The Netherlands Serving Europe Africa the Middle East and The Netherlands Phone 31 306 868 150 Midtronics China Chin...

Reviews: