background image

       
 
 

 

 

 
 
 
 
 
    
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
The MNCLIPPER works with the MidNite Solar Classic MPPT Charge Controller to provide 
the highest level of performance and protection possible. 

 
 

Features: 

 

Helps protect turbine from overspeed. 

 

Braking feature included. 

 

Convenient switching between run / turbine Stop. 

 

Settable voltage threshold for clipping. 

 

50 Amp pass-through. 

 

D.C. or Three Phase AC models with heavy duty three phase bridge rectifier. 

 

AC model Converts three phase AC input to D.C. for the Classic. 

 

Durable powdercoated chassis. 

 

MNSPD Surge protective devices (optional) can be added for protection against surges. 

 

Available in 1.5 and 4.0 KW models. 

MidNite Solar Clipper Instructions 

Summary of Contents for MNCLIPPER

Page 1: ...nient switching between run turbine Stop Settable voltage threshold for clipping 50 Amp pass through D C or Three Phase AC models with heavy duty three phase bridge rectifier AC model Converts three p...

Page 2: ...s or other electrical equipment Power from RE sources makes a very effective arc welder with dire consequences if one of the welded pieces is on your person Table of contents Theory of operation 3 Maj...

Page 3: ...ser adjustable emergency fail safe max voltage setting This will allow the clipper to keep the turbine under control if communications are lost with the Classic Caution Parts of the Clipper get hot du...

Page 4: ...t touch any internal components of the Clipper until all power has been removed and the Clipper has had time to cool down The internal fan is temperature controlled and may run anytime that power is a...

Page 5: ...8 of clearance on the sides and bottom and 24 above the Clipper are recommended The Clipper is somewhat heavy it is a good idea to be sure that the mounting surface can handle the weight Also ensure t...

Page 6: ...s not included Be sure to observe NEC mounting height requirements Mounting a Classic charge controller With an MNCCB L Left side mounting bracket Sold separately and three countersunk screws secure t...

Page 7: ...the wire gauge used based on the protection provided by the circuit breakers fuses On the following pages are drawings of knockout locations and more detailed wiring information Below are the torque...

Page 8: ...nockout Location Clipper Dimensions 25 411 Tall X 15 41 Wide 26 961 Tall including mounting brackets Shipping Weight 55 lbs Knockouts for MNEDC Circuit Breakers A circuit breaker is required for the i...

Page 9: ...on that came with your charge controller Observe proper polarity Severe damage could result from improper wiring Knockouts are located on the sides and bottom of the Clipper See Page 8 for knockout lo...

Page 10: ...to the documentation that came with your charge controller Observe proper polarity Severe damage could result from improper wiring Knockouts are located on the sides and bottom of the Clipper See Page...

Page 11: ...r to control the Clipper See page 12 and refer to the documentation that came with your Classic for details on how to set the Clipping Voltage It is still necessary to set the upper limit on the trimp...

Page 12: ...n finished push the ENTER button to save the changes Press the upper right soft key for VOLTS options Scroll to the right to select AUX2 Using the Up Down arrow keys select your Clipper type AC or DC...

Page 13: ...nging the Resistor Module The Clipper comes with a replaceable diversion load The diversion load is a resistor module available with different resistor values and configurations to provide a variety o...

Page 14: ...re sensors on the side of the resistor module Remove the terminals by pulling on the red handles Do not pull on the wires Step 2 Remove the four wires from the terminal block at the base of the resist...

Page 15: ...Classic manual for further troubleshooting If the turbine is still stalled Remove the brake slider plate and turn breakers to the off position to disconnect the turbine input If turbine does not spin...

Page 16: ...Clipper Instructions continued 16 P a g e 1 0 1 7 1 1 R E V E...

Page 17: ...Clipper Instructions continued 17 P a g e 1 0 1 7 1 1 R E V E...

Page 18: ...Clipper Instructions continued 18 P a g e 1 0 1 7 1 1 R E V E...

Page 19: ...Solar forum at http midniteftp com forum Not only will you find advice from others who have been there but also several of the folks at MidNite drop by to answer questions admire system photos and jus...

Page 20: ...e the defective product must be received no later than two 2 weeks after the end of the warranty period The product must be accompanied by proof of purchase and Return Authorization RA number issued b...