background image

 

 

 

                                      MIDEA 60Hz 

                      WINDOW MECHANICAL 

    

SIDE AIR DISCHARGE 

 

 
 
 
 

 

F SERIES 

                         

Summary of Contents for MWF1-07CMN1-NC0

Page 1: ...MIDEA 60Hz WINDOW MECHANICAL SIDE AIR DISCHARGE F SERIES ...

Page 2: ...s 28 6 1 Select the best location 28 6 2 Check off installation 28 6 3 How to drain 29 6 4 How to install 29 6 4 1 Installation of the housing 29 6 4 2 Installation of the unit into the housing 30 6 4 3 Installation of the unit into the wall 30 6 4 4 Installation steps 30 7 Operation characteristics 33 7 1 Cooling operation 33 7 2 Heating operation 33 7 3 Characteristic of temperature sensor 34 8 ...

Page 3: ...mproper wiring or installation may cause fore or electric shock Use the correctly rated breaker of fuse There is risk of fire or electric shock Do not modify or extend the power cable There is risk of fire or electric shock Do not install remove or reinstall the unit by yourself customer There is risk of fire electric shock explosion or injury Be caution when unpacking and installing the product S...

Page 4: ...losion or fire If strange sounds or small or smoke comes from product Turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill ...

Page 5: ...s works of art etc It is a consumer air conditioner not a precision refrigerant system There is risk of damage or loss of property Do not block the inlet or outlet of air flow It may cause product failure Use a soft cloth to clean Do not use harsh detergents solvents etc There is risk of fire electric shock or damage to the plastic parts of the product Do not touch the metal parts of the product w...

Page 6: ...or other health hazards 2 Function and control panel 2 1 Functions Operation mode Cooling Fan Optional mode Dry and Auto Fresh air switch Swing function Auto defrosting Anti freezing control in cooling mode or drying mode Prevent the water being freezed on evaporator by sensing the evaporator pipe temperature in cooling mode Time Delay Safety Restarting is for approx 3 minutes Auto restart When th...

Page 7: ...5 2 SA KC20 EE1 B8 MWE 07CM NB8 SA KC22 E1 B MWH 07CM 3 HT KC22 E4 MWH 07CM 4 SA KC25 FF B4 MWF 09CM NB4 PH KC25 FF B8 MWF 09CM NB8 16120300000134 16020300000116 ...

Page 8: ... C1 MWF1 12CMN1 NC1 UL KC32 F1F B4 MWF1 11CM BB4 UL KC35 FF B8 MWF 12CM BB8 SA KC35 N1 F1F B4 MWF1 12CMN1 NB4 UL KC35 F1F B8 MWF1 12CM BB8 6 HT KC28 E4 MWH 10CM HT KC32 E4 MWH 12CM 16020300000116 ON OFF 1 12 9 6 3 OFF AUTO SWING LOW COOL MED COOL HIGH COOL LOW FAN MED FAN HIGH FAN SELECTOR THERMOSTAT WAIT THREE MINUTES BEFORE RESTARTING COOLER 16020300000029 16120300000132 ...

Page 9: ...2 MWF 21CM NB2 PH KC61 N1 EF C1 MWF 21CMN1 NC1 SA KC46 F1F B4 MWF1 16CM NB4 SA KC53 FF B4 J MWF 18CM NB4 SA KC46 FF B4 J MWF 16CM NB4 SA KC61 F1F B4 MWF1 21CM NB4 SA KC61 FF B4 J MWF 21CM NB4 SA KC61 FA2 B5 MWH 21CM NB5 SA KC53 FA2 B9 MWF 18CM NB9 PH KC46 FF B7 MWF 16CM NB7 SA KC53 FF B9 MWF 18CM NB9 SA KC61 EF B5 MWE 21CM NB5 16020300000039 16020300000006 16020300000030 ...

Page 10: ...SA KC61 N1 FE1 B7 MWF 21CMN1 NB7 HT KC53 E4 MWH 18CM 11 SA KCD35 F1F B8 MWF1 12EM NB8 12 SA KCD46 FF B9 MWF 16EM NB9 SA KCD61 EF B5 MWH 21EM NB5 16020300A03579 16020300000044 4 16020300000007 16020300000009 ...

Page 11: ...9 13 SA KC25 F1F B4 MWF1 09CM NB4 PH KC20 F1F B8 MWF1 07CM NB8 PH KC25 F1F B8 MWF1 09CM NB8 UL1 KC20 N1 F1F I7 MWF1 07CMN1 MI7 14 HT KC22 F1E1 B8 MWF1 08CM NB8 16020300000010 16020300000037 ...

Page 12: ...10 15 CAUL KCD35 F1F6 B8 MWF1 12EM BB8 16 PH KC25 N1 F2F C1 MWF2 09CMN1 NC1 PH KC21 N1 F1F C0 MWF1 07CMN1 NC0 PH KC25 N1 F1F B9 MWF1 09CMN1 NB9 16020300001368 16020300000024 ...

Page 13: ...11 3 Dimension F E Series Dimension Mode W mm H mm D mm 7K 9K B4 B8 B9 450 346 535 12K 9K C1 600 380 560 10K HT 12K HT 560 400 640 16K 18K 21K 660 428 680 21K C1 660 428 780 MWF2 09CMN1 NC1 450 346 585 ...

Page 14: ...he important components and their function in what is called the refrigeration system This will help to understand the refrigeration cycle and the flow of the refrigerant in the cooling cycle For only cooling LIQUID SIDE GAS SIDE EVAPORATOR CONDENSER COMPRESSOR CAPILIARY TUBE ...

Page 15: ...H COOL HIGH FAN OFF LOW FAN LOW COOL 0 4 2 1 3 MAIN SWITCH COMPRESSOR THERMOSTAT BLUE WHITE N L 3 C 2 BLACK GREEN BLACK L BLACK BLACK BLUE R C S BLUE CAPACITOR CAPACITOR RED RED FAN MOTOR RED YELLOW M BLACK BLACK LOUVER MOTOR 1 1b 1a LOUVER SWITCH O T P RED G RED 202020890035 ...

Page 16: ...14 2 HT KC22 E4 MWH 07CM PH KC20 FF B8 MWF 07CM NB8 16020300001102 ...

Page 17: ...OWN OR BLACK L HIGH COOL HIGH FAN OFF LOW FAN LOW COOL 0 4 1 3 MAIN SWITCH M M COMP THERMOSTAT G Y OR GREEN BLUE OR WHITE N E RED RED YELLOW FAN CAP RED BLUE E BLACK CAP R S C L C E M BLACK BLACK LOUVER MOTOR 1 1b 1a RED LOUVER SWITCH 2 BLACK BLACK BLUE 16020300001107 ...

Page 18: ...OOL HIGH FAN OFF LOW FAN LOW COOL 0 4 2 1 3 MAIN SWITCH M M COMP THERMOSTAT G Y OR GREEN BLUE OR WHITE N E RED RED YELLOW BLUE BROWN BLACK FAN CAP RED BLUE E BLACK CAP R S C L C E MID FAN MID COOL M BLACK BLACK LOUVER MOTOR WHITE 1 1b 1a RED LOUVER SWITCH A 202021490169 ...

Page 19: ... FAN OFF LOW FAN LOW COOL 0 4 2 1 3 MAIN SWITCH COMPRESSOR THERMOSTAT BLUE WHITE N L C BLACK GREEN BLACK L BLACK BLACK BLUE R C S BLUE CAPACITOR CAPACITOR RED FAN MOTOR RED YELLOW M RED BLUE LOUVER MOTOR 1 1b 1a LOUVER SWITCH O T P RED E RED G Y 16020300001084 ...

Page 20: ...25 F1F B8 MWF1 09CM NB8 UL1 KC20 N1 F1F I7 MWF1 07CMN1 MI7 HT KC22 F1E1 B8 MWF1 08CM NB8 PH KC21 N1 F1F C0 MWF1 07CMN1 NC0 PH KC25 N1 F1F B9 MWF1 09CMN1 NB9 POWER BROWN OR BLACK L HIGH COOL HIGH FAN OFF LOW FAN LOW COOL 0 4 2 1 3 MAIN SWITCH M M COMP THERMOSTAT G Y OR GREEN BLUE OR WHITE N E RED RED YELLOW BLUE BROWN BLACK FAN CAP RED BLUE E BLACK CAP R S C L C E MID FAN MID COOL M BLACK BLACK LOU...

Page 21: ...COOL HIGH FAN OFF LOW FAN LOW COOL 0 4 1 3 MAIN SWITCH M M COMP THERMOSTAT G Y OR GREEN BLUE OR WHITE N E RED RED YELLOW BLUE BROWN BLACK FAN CAP RED BLUE E BLACK CAP R S C L C E MID COOL M BLACK BLACK LOUVER MOTOR WHITE 1 1b 1a RED LOUVER SWITCH 6 5 202021990437 ...

Page 22: ...B4 PH KC46 FF B7 MWF 16CM NB7 POWER BROWN OR BLACK L HIGH COOL HIGH FAN OFF LOW FAN LOW COOL 0 5 4 3 6 MAIN SWITCH M M COMP THERMOSTAT G Y OR GREEN BLUE OR WHITE N E RED RED YELLOW BLUE BROWN BLACK FAN CAP RED BLUE E BLACK CAP R S C L C E MID COOL M BLACK BLACK LOUVER MOTOR WHITE 1 1b 1a RED LOUVER SWITCH 1 C L DEFROSTING THERMOSTAT RED 16020300001137 ...

Page 23: ... CAP RED BLUE E BLACK CAP R S C L C E LOW FAN MID COOL M BLACK BLACK LOUVER MOTOR WHITE 1 1b 1a RED LOUVER SWITCH A 202021890195 HIGH COOL HIGH FAN OFF LOW FAN LOW COOL 0 1 5 6 4 MAIN SWITCH COMPRESSOR THERMOSTAT BLUE BLUE N L C BLACK G Y BROWN L BROWN BLUE R C S BLUE CAPACITOR CAPACITOR RED RED FAN MOTOR RED YELLOW M BLACK BLACK LOUVER MOTOR 1 1b 1a LOUVER SWITCH O T P RED E 3 WHITE BLACK MID COO...

Page 24: ...VER MOTOR 1 1b 1a LOUVER SWITCH O T P RED E RED 3 COMPRESSOR POWER RED BLUE BLUE LAMP C L THERMOSTAT YELLOW BLACK G Y G Y RED LOW FAN 202021990025 HIGH COOL HIGH FAN OFF LOW FAN LOW COOL 0 1 5 6 4 MAIN SWITCH COMPRESSOR DEFROSTING THERMOSTAT BLUE BLUE OR WHITE N L C BLACK G Y OR GREEN BROWN OR BLACK L BLACK BLACK R C S BLUE CAPACITOR CAPACITOR FAN MOTOR RED YELLOW M BLACK BLACK LOUVER MOTOR 1 1b 1...

Page 25: ...23 13 UL KC32 F1F B4 MWF1 11CM BB4 UL KC35 F1F B8 MWF1 12CM BB8 16020300001124 ...

Page 26: ... F1F B4 MWF1 21CM NB4 SA KC53 FF B4 J MWF 18CM NB4 SA KC61 FF B4 J MWF 21CM NB4 SA KC53 FF B9 MWF 18CM NB9 SA KC61 EF B5 MWE 21CM NB5 15 HT KC53 E4 MWH 18CM SA KC61 FA2 B5 MWH 21CM NB5 1602030000112 8 16020300001098 ...

Page 27: ...R G BLUE OR WHITE N 3 1 HIGH HEAT LOW HEAT HIGH FAN LOW FAN A 1 1a 1b LOUVER SWITCH M LOUVER MOTOR RED E BLACK WHITE RED BLACK BROWN BLUE CAPACITOR COMPRESSOR BLACK R C S BLUE CAPACITOR O T P G Y FAN MOTOR L C 5 RED BLUE LAMP RED YELLOW RED Thermal Cut off PTC HEATER L C POWER TERM BLACK RED RED DEFROSTING THERMOSTAT BLUE BLUE M OPTIONAL OPTIONAL OPTIONAL 16020300001094 ...

Page 28: ...26 17 SA KCD61 EF B5 MWH 21EM NB5 16020300001113 ...

Page 29: ...27 18 PH KC25 N1 F2F C1 MWF2 09CMN1 NC1 ...

Page 30: ... slight angle so that an condensate formed will not enter the room about 3 4o with level 6 Install the unit with its bottom portion 75 150cm above the floor level 7 The power cord must be connected to an independent circuit The yellow green wire must be grounded 6 2 Check off installation The setting conditions must be checked prior to initial starting The under mentioned items are especially impo...

Page 31: ... secure with screws provide 4 Connect the drain hose to the outlet located at one side of the drain pan You can purchase the drain hose or tubing locally to satisfy your particular needs Drain hose is not supplied 6 4 How to install 6 4 1 Installation of the housing Step1 Remove the air conditioner from it s packaging remove fixing screws and slide the air conditioner out of it s housing Refer to ...

Page 32: ...st the rear of the housing Care is required to ensure the foam sealing strips on the housing remain in position Connect the air conditioner to the power and position excess cord length beneath the air conditioner base Engage the chassis fixing brackets into the bottom housing rail and secure to the base with the screw provided Remove the front panel from it s carton and plastic bag and fit as per ...

Page 33: ...hassis fixing brackets as shown in Fig 3A Remove one screw on the chassis fixing bracket then remove the chassis fixing bracket Remove the two screws located on the back of the cabinet as shown in Fig 3B Remove one screw on the chassis fixing bracket then remove the chassis fixing bracket as shown in Fig 3C Remove the four screws located on both sides and the back of the cabinet as shown in Fig 3D...

Page 34: ...r see Fig 7 4 Push the unit chassis into the cabinet see Fig 8 5 Fix the chassis and cabinet see Fig 5 Step 4 Install the frame 1 Install the frame See Fig 8 2 Fix the screws on the frame See Fig 3A 3B 3C 3D Step 5 Install the air filter and front panel 1 Install the air filter into the frame s slot from upside to underside See Fig 2 2 Hang the front panel on the frame s buckle then press the fron...

Page 35: ...33 7 Operation characteristics 7 1 Cooling operation 7 2 Heating operation ...

Page 36: ...0 52 3 1918 1 37 1988 26 9 5507 53 3 0707 0 35 2024 27 9 1245 54 2 959 1 33 3269 28 8 7198 55 2 8442 2 31 5635 29 8 3357 56 2 7382 3 29 9058 30 7 9708 57 2 6368 4 28 3459 31 7 6241 58 2 5397 5 26 8778 32 7 2946 59 2 4468 6 25 4954 33 6 9814 60 2 3577 7 24 1932 34 6 6835 61 2 2725 8 22 5662 35 6 4002 62 2 1907 9 21 8094 36 6 1306 63 2 1124 10 20 7184 37 5 8736 64 2 0373 11 19 6891 38 5 6296 65 1 96...

Page 37: ...ay be dirty Clean filter Refer to Care and Cleaning section To defrost set selector to FAN Thermostat set too cold for night time cooling To defrost the coil set selector to a FAN position Then set thermostat to a warmer position Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filter air restricted Clean air filter Refer to Care and Cle...