Service Manual_2018-V2.0
20
All accessories in the refrigerating chamber should be
removed before dismantling the air duct mask.
1
)
Remove the 6 screws fixing the air duct mask.
2
)
Disconnect the wiring connector and dismantle the air
duct mask.
Fan motor of air duct
The air duct mask should be removed before dismantling
the fan motor.
1
)
Remove the aluminized tape around the fan;
2
)
Separate the 4 rubber pop-rivet fixing the fan and
take it down.
8.5 Evaporator and temperature sensing system
Evaporator in refrigerating chamber
1
)
Move the air duct mask in refrigeration chamber.
2
)
Sconnect all connectors.
3
)
Move the welding on inlet and outlet tubes.
4
)
Move the evaporator.
Components on the evaporator
None
Summary of Contents for HS-202WEN
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None ...
Page 16: ...Service Manual_2018 V2 0 16 6 3 Circuit diagram ...
Page 32: ...Service Manual_2018 V2 0 32 12 Troubleshooting Method 12 1 Not cooling ...
Page 35: ...Service Manual_2018 V2 0 35 12 6 Light is not on ...