Service Manual_2020-V3.0
21
6.5 Welding point in the compressor case
Welding point
Pipe outer diameter (mm)
1-anti-condensation tube and outlet of venting connection
tube
Steel pipe:
Φ4.0
Steel pipe:
Φ4.0
2-outlet of anti-condensation tube and outlet of right
condenser tube
Steel pipe:
Φ4.0
Steel pipe:
Φ4.0
3-Outlet of condenser tube and inlet of dry filter
Steel pipe:
Φ4. 0
Copper pipe:
Φ4.0
4-Outlet of dry filter and inlet of freezer capillary
Copper pipe: Φ2.8
Copper pipe: Φ1.8
5-Heat transition tube and Suction connection tube
Copper pipe:
Φ6.0
Copper pipe:
Φ6.0
6-Suction connection pipe and compressor intake tube
Copper pipe:
Φ6.0
Copper pipe:
Φ8.17
7-Compressor outlet tube and inlet of venting connection tube Copper pipe:
Φ6.17
Steel pipe:
Φ4.0
8-Compressor process tube and refrigerant filling tube
Copper pipe:
Φ8.17
Copper pipe:
Φ6.0
Summary of Contents for HD-676REWN
Page 5: ...Service Manual_2020 V3 0 5 1 Significant update notes None...
Page 24: ...Service Manual_2020 V3 0 24 Light of the freezing...
Page 47: ...Service Manual_2020 V3 0 47 11 Troubleshooting Method 11 1 No cooling Air cooling Electronic...
Page 48: ...Service Manual_2020 V3 0 48...
Page 49: ...Service Manual_2020 V3 0 49 11 2 No working of compressor...
Page 50: ...Service Manual_2020 V3 0 50 11 3 Inside frosting no defrosting...
Page 51: ...Service Manual_2020 V3 0 51 11 4 Inside frosting no defrosting Maintenance guidelines...
Page 52: ...Service Manual_2020 V3 0 52 11 5 Light is not on...
Page 53: ...Service Manual_2020 V3 0 53 11 6 Fan failure 11 7 Defective defrost circuit...
Page 54: ...Service Manual_2020 V3 0 54 11 8 Noise 11 9 Air duct not operated...
Page 55: ...Service Manual_2020 V3 0 55 11 10 Ice makernot make ice Option...