Service Manual_2018-V2.0
47
Different figures represent different functions:
1) When display “0”, the refrigerator will not enter into anyone mandatory mode, and quit the mandatory
mode.
2) When display “1”, the compressor will start working last for 36 hours, then it will quit this mode
automatically and back to normal working status.
3) When display
“3”, the ice maker will turn over the ice for twice, then intake water.
10.6Control of ice maker
1) Ice maker on/off
Press “ICE ON” button to turn off/on ice maker, the default setting is on.
2
)
Options for ice /cooling water
Press
the button of “CUBED”/“WATER”/”CRUSHED” , the corresponding icons will light on .The working
time of the power-on filter accumulates. When the filter works for 150 days, the filter icon shall light up to
prompt the user to replace the filter and shall flash to prompt the user to replace the filter
after 180 days. Long press the "filter time reset" button for 3 seconds to perform the function of
"FILTER RESET". At this time the filter timing shall be reset;
10.7 Celsius Fahrenheit conversion
Long press “Energy Saving” button for 3s to convert the temperature from Celsius to Fahrenheit and
Back again.
10.8Fault code and solutions
Note: midea full common fault code, combined with the actual product display reference.
Fault code
Fault content
Steps for maintenance methods
E0
fault of ice maker
Step 1:Check whether the terminal of ice maker in main
control board is well stuck, pull out the terminal and re-stick it
in place
Step 2: Check to see if ther
e’re foreign matters on the terminal
Step 3: Check whether the terminal of ice maker is well
E1
Temperature
sensor fault in
refrigerating
chamber
Step 1: Check whether the terminal of temperature sensor in
main control board is well stuck, pull out the terminal and
re-stick it in place
Step 2: Check to see if ther
e’re foreign matters on the terminal
Step 3: Inspect the refrigerating sensor whether contact is
bad, and resend contact the fast connector
Step 4: Replace main control board
E2
Temperature
sensor fault in
freezing chamber
Step 1: Check whether the terminal of temperature sensor in
main control board is well stuck, pull out the terminal and
re-stick it in place
Step 2: Check to see if there
’re foreign matters on the
terminal. Pull out the defrost sensor in freezing chamber
according to the method in described in Article 9.2 and then
inspect the sensor against the resistance value table in 9.3.
Step 3: Replace main control board
Summary of Contents for HC-957WEN
Page 5: ...Service Manual_2018 V2 0 5 1 Significant update notes None...
Page 24: ...Service Manual_2018 V2 0 24 7 3Circulating route of cooling air...
Page 52: ...Service Manual_2018 V2 0 52 12 Troubleshooting Method 12 1 No cooling Air cooling Electronic...
Page 53: ...Service Manual_2018 V2 0 53 12 2 No working of compressor 12 3 Inside frosting no defrosting...
Page 54: ...Service Manual_2018 V2 0 54 12 4 Inside frosting no defrosting Maintenance guidelines...
Page 55: ...Service Manual_2018 V2 0 55 12 5 Light is not on 12 6Fan failure...
Page 56: ...Service Manual_2018 V2 0 56 12 7Defective defrost circuit 12 8Noise...
Page 58: ...Service Manual_2018 V2 0 58 13 Figures and details of repair parts See this section in the TSP...