Storage Electric Water Heater

The diagram above is just for reference. Please take the

appearance of the actual product as the standard. 

Instruction Manual

      Model: D30-15FA2

                  D50-15FA2

                  D80-15FA2

                    D100-15FA2

Thank you very much for purchasing our water heater. 

Before installing and operating your water heater, please 

read this manual carefully and keep it for future reference.

Summary of Contents for D100-15FA2

Page 1: ...appearance of the actual product as the standard Instruction Manual Model D30 15FA2 D50 15FA2 D80 15FA2 D100 15FA2 Thank you very much for purchasing our water heater Before installing and operating...

Page 2: ...sed by wrong installation or failing to comply with following instructions included in this pamphlet For more detailed installation and maintenance guidelines please refer to below chapters TABLE OF C...

Page 3: ...outflow pipe must open wide in the air The pressure relief valve need to be checked and cleaned regularly so as to make sure it will not be blocked Before installing this water heater check and confi...

Page 4: ...cord is damaged the special supply cord provided by the manufacturer must be selected and replaced by the professional maintenance personnel If any parts and components of this electrical water heate...

Page 5: ...AM Note All dimensions are in mm D50 15FA2 385 705 100 200 D80 15FA2 450 758 100 200 D100 15FA2 450 908 100 200 A B C D D30 15FA2 340 570 100 200 Heating Element Heating Indicator Light Thermal Cut Ou...

Page 6: ...without sun scorched and rain drenched However in order to reduce the pipeline heat losses the installation position of the heater shall be closed to the location shall be as near as possible to the...

Page 7: ...ensured that there is a clearance not less than 0 2m on the right side of the electric heater to convenient the maintenance of the heater if necessary If the users want to realize a multi way supply...

Page 8: ...danger like electric shock 7 4 METHODS OF USING NOTE During normal operation the inlet valve shall be always kept open First open any one of the outlet valves at the outlet of the water heater then o...

Page 9: ...ct with the professional personnel for repair No water coming out of the hot water outlet The water temperature is too high Water leak 1 The running water supply is cut off 2 The hydraulic pressure is...

Page 10: ...2 528 0 831 3 498 65 7 69 9 29 0 29 0 2 788 31 9 578 C Description t i n U e u l a V r e t e m a r a P k Value k Smart control compliance smart Smart control factor SCF Conversion coefficient CC Ambi...

Page 11: ...Normalised value of the average temperature p Volume that delivered water of at least 40 V40exp L Calculated volume that delivered hot water of at least 40 V40 L 68 0 60 2 10 3 60 1 39 4 65 9 0 23 0 0...

Page 12: ...trol compliance smart Smart control factor SCF Conversion coefficient CC Ambient correction term Qcor kWh Referenct energy Qref kWh Useful energy content QH2O kWh Correction ratio of reference and use...

Page 13: ...ping Tset Average water temperature of outlet warm water p Average water temperature of inlet cold water c Normalised value of the average temperature p Volume that delivered water of at least 40 V40e...

Page 14: ...www midea com global The product is subject to change without notice Please keep this manual properly Midea Italia S r l A Socio Unico Viale Bodio 29 20158 Milano MI www midea com it...

Page 15: ...del prodotto concreto Scaldabagno elettrico Manuale Utente e di installazione Modello D30 15FA2 D50 15FA2 D80 15FA2 D100 15FA2 I disegni e le informazioni grafiche contenute in questo volume sono sol...

Page 16: ...o rispetto delle istruzioni incluse in questo libretto Per delle linee guida su installazione e manutenzione pi dettagliate fare riferimento ai capitoli sotto TABELLA DEI CONTENUTI TITOLO Pagina 1 Pre...

Page 17: ...del peso dell elettrodomestico completamente pieno d acqua senza piegarsi o formare crepe In caso contrario necessario adottare delle misure di rafforzamento La valvola di rilascio pressione collegata...

Page 18: ...tituito da personale dimanutenzione certificato dal produttore Se altre parti o componenti di questo scaldabagno sono danneggiate contattare il centro di supporto clienti per richiedere la riparazione...

Page 19: ...450 450 B 570 705 758 908 C 100 100 100 100 D 200 200 200 200 Nota tutte le dimensioni sono in mm 2 3 Diagramma cavi interni 1 2 Protezione termica Termostato Marrone L N E Blu Giallo Verde SCHEMA ELE...

Page 20: ...essivamente appendere lo Tassello a espansione con gancio Fig 2 Installare la presa di corrente sulla parete I requisiti della presa sono i seguenti 250V 10A fase singola tre POLI Si consiglia di posi...

Page 21: ...iscelatore Vasca acqua Triplo collegamento Uscita acqua calda Ingresso acqua fredda Fig 5 NOTA Assicurarsi di utilizzare gli accessori forniti dalla nostra societ durante l installazione di questo sca...

Page 22: ...eve essere smontato solo da professionisti del settore Contattare un professionista per la manutenzione In caso contrario la nostra societ non si assume la responsabilit per eventuali Pulsante riprist...

Page 23: ...re lo scaldabagno di nuovo dopo aver aumentato la pressione idraulica 3 Aprire la valvola di ingresso dell acqua La temperatura dell acqua troppo elevata Guasti del sistema di controllo temperatura Co...

Page 24: ...9 k smart SCF CC Qcor kWh Qref kWh QH2O kWh Qref QH2O kWh Qtest_elec kWh T3 T5 Mact kg Cact L Qelec kWh wh AEC kWh Descrizione Parametro Valore Unit Descrizione Parametro Valore Unit Tset p c p V40exp...

Page 25: ...o annuale Classe di Efficienza energetica di riscaldamento d acqu Temperatura acqua senza tapping Temperatura acqua media uscita acqua tiepida Temperatura acqua media ingresso acqua fredda Valore norm...

Page 26: ...annuale Classe di Efficienza energetica di riscaldamento d acqu Temperatura acqua senza tapping Temperatura acqua media uscita acqua tiepida Temperatura acqua media ingresso acqua fredda Valore normal...

Page 27: ...nuale Classe di Efficienza energetica di riscaldamento d acqu Temperatura acqua senza tapping Temperatura acqua media uscita acqua tiepida Temperatura acqua media ingresso acqua fredda Valore normaliz...

Page 28: ...www midea com global Questo prodotto sar soggetto a cambiamenti senza preavvisi Conservare correttamente questo manuale Midea Italia S r l A Socio Unico Viale Bodio 29 20158 Milano MI www midea com it...