Service Manual
, 2016-12
18
/
51
5.3
制冷温度
Inside temperature
Temperature tolerance ≤ 2°C
Compartment
The highest (
o
C)
Lowest (
o
C)
Freezing
-14
-24
Refrigerating
9
1
Variable temperature
/
/
5.4
除霜部件
Defrosting parts
Defrosting period
Initial defrosting period
Normal defrosting period
Temperature is lower than 0
o
C
6~24 hours
Defrosting sensor
NTC
B3839
Defrosting temperature controller
/
/
Thermal fuse
Cant be restored
77
o
C
Defrosting heater in freezing chamber
/
Defrosting heater
230V/250W
5.5
电路图
Circuit diagram
MAIN PCB