Service Manual
, 2016-12
13
/
42
5.
Product specification
5.2
Electrical parameters
Product Name
UR-BD390WE-ST
CE-BD390WE-ST
/
Product Code
22031010001341
22031010001361
/
Name
Item
Type
Specification
Specification
Specification
Compressor
Compressor
/
EZ80H1A-
USCL
LJ118DY1
/
Starter
PTC
QP2-4R7
LPC319D-
01/QPE2-
A15MD3
/
Overload protector
OLP
DRB31T61A1
BT69-
120/DRB246N61
A2/3TM213NF1
/
Winding resistance of
compressor wiring
terminal
Rmc
:
4.6
~
4.74Ω
Rsc
:
6.16
~
6.3Ω
Rms=Rmc+Rsc
Rmc
:
8.67
~
11.73Ω
Rsc
:
16.15
~
21.85Ω
Rms=Rmc+Rsc
/
Variable frequency
driver board
/
/
/
/
Motor
Fan motor of the
freezing chamber
DC
DC12V
DC12V
/
Ventilation door of the
refrigerating chamber
/
/
/
/
Condensation fan
/
/
/
/
Lights inside
the refrigerator
Lights inside the
freezing chamber
LED
DC12V
DC12V
/
Lights inside the
refrigerating chamber
/
/
/
/
Switch of the
refrigerator door
Cylindrical
switch
Cylindrical switch
/
5.3Inside temperature
Temperature tolerance ≤ 2
o
C
Compartment
The highest (
o
C)
Lowest (
o
C)
Freezing
-14
-21
Refrigerating
/
/
Variable temperature
/
/
5.4Defrosting parts
Defrosting period
Initial defrosting period
Normal defrosting period
/
/
Defrosting sensor
NTC
B3839
Thermal fuse
Can’t be restored
77
o
C
Defrosting heater in freezing chamber
Steel pipe
115V/200W
230V/
Summary of Contents for 22031010001341
Page 5: ...Service Manual 2016 12 5 42 1 Safety Warning Code 1 1Warning for operation safety ...
Page 6: ...Service Manual 2016 12 6 42 ...
Page 7: ...Service Manual 2016 12 7 42 ...
Page 8: ...Service Manual 2016 12 8 42 1 2 冷媒安全须知 ...
Page 15: ...Service Manual 2016 12 15 42 ...
Page 33: ...Service Manual 2016 12 33 42 11 Troubleshooting Method 11 1 No refrigeration ...
Page 34: ...Service Manual 2016 12 34 42 11 2 Compressor failure ...
Page 35: ...Service Manual 2016 12 35 42 11 3 Defrosting is not working ...