2.4
Voltages, types of connection and versions
Standard version three phase
with neutral and earth
Voltage three-phase 3N~400 V
50/60Hz - 3L + N + PE
Special version three-phase
without neutral
Voltage three-phase 3~ 230 V
50/60Hz - 3L + PE
2.5
Mains fuses
Type
211 / 422
(422 with
two supply cables)
311
411 / 422
(422 with
one supply cable)
Power
7.5 KW
11 KW
11.4 KW
15 KW
15 KW
22 KW
AC 230V
32.6 A
-
-
-
-
3AC 230V
18.8 A
27.6 A
27.6 A
37.65 A 37.65 A
-
3NAC 400V
10.8 A
15.8 A
15.8 A
21.7 A
21.7 A
31.6 A
2.6. Electrical connection
This appliance must be installed, commissioned and serviced by a qualified person in accordance with national
and local regulations in force in the country of installation. Ensure the plug/socket is accessible at all times. This
appliance must be earthed.
a) Check that the specifications of the electrical mains correspond to those given on the rating plate. This plate is
located on the control panel inside the door.
b)
Means of isolation with at least 3mm contact separation in all poles must be incorporated into the fixed wiring of this
appliance. The fixed wiring insulation must be protected by insulated sleeving having a temperature range of at least 60
Deg C. Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent
elastomer sheathed cord (code 6024-IEC 57).
c)
An equipotential bonding terminal is provided to allow cross bonding with other equipment.
d)
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons.
6
22 with
two
supply cable
s
2 x 11.4
KW
2
X 15
KW
-
-
2
x 16.5
A
2 x 21.7
A
-
-
Summary of Contents for frifri Super Easy 211