5
ENGLISH
SECTION 2 - INSTALLATION
IMPORTANT:
Additional electrical information is provided on the oven's serial plate, and on the wiring diagram inside the
machinery compartment.
WARNING
Keep the appliance area free and clear of combustibles.
CAUTION
For additional installation information, refer to the following documents:
PS360 Pre-Installation Procedures Manual
(Middleby Marshall P/N 88210-0024)
PS360 Installation Manual
(Middleby Marshall P/N 88210-0025)
Or, contact your local Authorized Service Agent.
NOTE
There must be adequate clearance between the oven and combustible construction. Clearance
must also be provided for servicing and for proper operation.
NOTE
An electrical wiring diagram for the oven is located inside the machinery compartment.
NOTE
All aspects of the oven installation, including placement, utility connections, and ventilation requirements, must
conform with any applicable local and national codes. These codes supercede the requirements and guide-
lines provided in this manual.
NOTE
In U.S.A., the oven installation must conform with local codes, or in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1. The oven, when installed, must be electrically grounded in accordance
with local codes, or in the absence of local codes, with the National Electrical Code (NEC), or ANSI/NFPA70.
NOTE
In Canada, the oven installation must conform with local codes, or in the absence of local codes, with the
Natural Gas Installation Code, CAN/CGA-B149.1, or the Propane Gas Installation Code, CAN/CGA-B149.2, as
applicable. The oven, when installed, must be electrically grounded in accordance with local codes, or in the
absence of local codes, with the Canadian Electrical Code CSA, C22.2, as applicable.
NOTE
For Australian installation, the oven installation must conform with AGA Code, AG601, and with any require-
ments of the appropriate statutory authority.
E. Electrical specifications - for electrically-heated ovens
Main Blower
Control
Current
k W
Voltage
Circuit Voltage
Phase
Freq.
Draw
Rating
Poles
Wires
208-240V
120V
3 Ph
60 Hz
67.3A at 208V
26.0 kW at 208V
4 Pole
5 Wire (3 hot, 1 neut, 1 gnd)
(with 3 Ph blower motors)
58.4A at 240V
26.0 kW at 240V
208-240V
120V
3 Ph
60 Hz
67.3A at 208V
26.0 kW at 208V
4 Pole
5 Wire (3 hot, 1 neut, 1 gnd)
(with 1 Ph blower motors)
58.4A at 240V
26.0 kW at 240V
200-220V (export)
120V (transfomer)
3 Ph
50/60 Hz
67.3A at 208V
24.3 kW at 208V
3 Pole
4 Wire (3 hot, 1 gnd)
53.5A at 220V
20.4 kW at 220V
240V (export)
120V (transformer)
3 Ph
50/60 Hz
58.4A
26.0 kW
3 Pole
4 Wire (3 hot, 1 gnd)
380V (export)
120V (transformer)
3 Ph
50/60 Hz
36.8A
24.3 kW
3 Pole
4 Wire (3 hot, 1 gnd)
400-416V (export)
120V (transfomer)
3 Ph
50/60 Hz
33.8A
24.3 kW
3 Pole
4 Wire (3 hot, 1 gnd)
480V
120V (transformer)
3 Ph
60 Hz
29.2A
26.0 kW
3 Pole
4 Wire (3 hot, 1 gnd)
SECTION 1 - DESCRIPTION
WARNING
Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no
obstructions around or underneath the oven.
All manuals and user guides at all-guides.com