Quick Start Guide
UPS Online Network Interface Card
UPS-OLIPCARD
NOTE
: The Middle Atlantic UPS-OLIPCARD
is hot-swappable, so you do not need to turn
off the device to install it.
WARNING
: Unplug and allow the equipment to fully discharge before
performing installation steps.
AVERTISSEMENT
: Débranchez et laissez l'appareil se décharger
complètement avant peforming étapes d'installation.
WARNING
: For safety instructions, refer to the UPS-OLIPCARD User
Manual
at www.middleatlantic.com.
AVERTISSEMENT
: Pour obtenir des instructions de sécurité, se reporter
à la UPS-OLIPCARD User Manual
à www.middleatlantic.com.
1. Remove the two retaining
screws of the expansion slot,
and then remove the cover.
2. Install the Middle Atlantic
UPS-OLIPCARD into the
expansion slot.
3. Insert and tighten the retaining
screws.
4. Connect an Ethernet cable to the
Ethernet port of the Middle Atlantic
UPS-OLIPCARD.
Definitions for LED Indicators
5. You can modify the IP Address,
Subnet Mask, and Gateway
address for the device’s MAC
address listed in the Device
Network Settings window, as
shown in Figure 2.
The factory
default IP Address is
192.168.20.177
and the default
Subnet Mask is
255.255.255.0
.
6. Modify the IP, Subnet Mask, or
Gateway Address. Enter the new
addresses into the corresponding
fields, and then click
Save
.
Link LED color
Off
On (Yellow)
Tx/Rx LED color
Off
On (Green)
Flashing
Condition
The UPS-OLIPCARD is not
connected to the Network or the UPS
UPS-OLIPCARD power is off
The UPS-OLIPCARD is
connected to the Network
The UPS-OLIPCARD power is off
The UPS-OLIPCARD power is on
• Receiving or transmitting data packets
• Reset finished
Step 1. Hardware Installation
Figure 1. The main window of the Middle Atlantic Products UPS-IPCARD Setup Utility.
Figure 2. The Device Network setting window.
Ethernet Port
Tx/Rx Indicator
LINK Indicator
Universal Port
Tx/Rx
Link
Universal
UPS-OLIPCARD
Step 2. Configure the IP address for the UPS-OLIPCARD
Method 1: Using the UPS-IPCARD Setup Utility
4. Select the UPS-OLIPCARD you are setting up. Click
Tools >
Device Setup
, or double click the card you wish to configure from the
list shown.
INSTALLATION
• An Intelligent UPS Online Network Interface Card allowing a UPS
system to be managed, monitored, and configured remotely via the
web.
• Access the SNMP Card Configuration Tool, firmware updates, and
the UPS Online Network Interface Card User Manual at
www.middleatlantic.com.
PRODUCT FEATURES
I-00789 Rev E
NOTE
: If you have any issues acquiring the software, please contact
support at 1-800-266-7225.
1. After acquiring the
UPS-IPCARD Setup Utility software,
double
click the installation file
MAP_SNMP_Setup.msi
to begin the
installation.
2. After the installation is complete, run the Middle Atlantic
UPS-OLIPCARD Setup Utility by selecting
All Programs >
Middle Atlantic Products > UPS-IPCARD Setup Utility
.
3. The main dialog of the UPS-IPCARD Setup Utility is shown in
Figure 1. The configuration tool shows all network interface cards
present on the same network subnet. Click
Refresh
to search the