3 of 4
Specifi cations
External Connections
Primary Analogue Inputs
Mic / Line inputs - balanced XLR
connectors - 10 kΩ load
Primary Analogue Outputs
Main Outputs - balanced XLR
connectors - 50 Ω source
Primary Digital Inputs
XLR connectors - 110R
AES50 Connections
Neutrik etherCON with status
indication
Diagnostic Connection
9 W female ‘D’-type connector
Power Connections
IEC mains inlet - 100 - 240 V
AC~50 - 60 Hz ±10%
Audio Electronic Specifi cations
Maximum Input Level
Mic/Line (at unity gain)
+21 dBu
Mic/Line (at -2.5 dB gain)
+24 dBu
CMR at 1 KHz (typical)
Mic (at unity gain)
> -70 dB
Mic (at 40 dB gain)
> 90 dB
Noise
Mic EIN at 40 dB gain
-126 dBu
Output noise at unity gain
-87 dBu
Frequency Response
(20 Hz - 20 kHz),
±0.5 dB
relative to 1 kHz
Distortion at 1 kHz
Input to output (0 dB)
< 0.01%
Crosstalk at 1 kHz
Channel to channel
< -90 dB
Maximum Output Level
Line outputs (into 600R)
+21 dBu
Dynamic Range at 1 kHz
22 Hz - 22 kHz (at unity gain)
> 108 dB unweighted (20 Hz - 20 kHz)
Power Requirements
Voltage
100 V AC to 240 V AC ±10%
Frequency
50 Hz to 60 Hz
Consumption <150
W
Physical
Height
Approx 88.1 mm (2U)
Width
Approx 482.6 mm (19.0")
Depth
Approx 380 mm (15.0")
Net Weight
Approx 5 kg (11 lbs)
Shipping Weight
Approx 6 kg (13.2 lbs)
Operating temperature range
+5°C to 45°C
Storage temperature range
-20°C to +60°C
Neutrik and etherCON are registered trademarks of Neutrik AG
8-Input/8-Output/8-AES/EBU Stagebox
with MIDAS Mic Preamps and
Dual-Redundant AES50 Networking
I/O Interfaces
DL155