Micsig CP2100A User Manual Download Page 6

 

6

  / 

10

 

 

3.

 

Specifications 

Model 

CP2100A 

CP2100B 

Bandwidth 

DC~800KHz 

DC~2MHz 

Rise time 

437.5ns 

140ns 

Range 

10A/100A 

Output sensitivity 

0.1V/A

10A

 

0.01V/A

100A

 

DC accuracy (typical) 

3%

±

50mA

10A

 

4%

±

50mA

100A

500mA~40Apk

 

15%

100A

40Apk~100Apk

 

Signal delay 

150ns

10A

 

200ns

100A

 

DC linearity (typical) 

typical on page 6 

Measuring range 

50mA~10Apk

10A

 

1A~100Apk

100A

 

Maximum measuring current 

100Apk

70.7Arms

DC+ACpk

 

200Apk-pk

70.7Arms

AC

 

Maximum working voltage 

CAT III 300V CAT II 600V 

Maximum floating voltage 

CAT III 300V CAT II 600V 

Maximum conductor diameter 

13mm 

Overload indication 

The buzzer sounds long and the button light flashes 

Supplied power 

DC 5V 

Probe head size 

11*6.1*2.5cm 

Control box size 

10.8*5.6*2.6cm 

Length   

228cm 

Weight   

290g 

Package weight   

1000g 

Package dimensions 

29.5*23.6*5.7cm 

Operating temperature 

0~50°C 

Storage temperature 

-20

~80

 

Operating humidity 

5%~95%(0~40

, No condensation) 

5%~65%(40

~50

, No condensation) 

Operating altitude 

3000m 

Storage altitude 

12000m 

 

Summary of Contents for CP2100A

Page 1: ...CP2100A CP2100B ...

Page 2: ...l and any information contained in it including but not limited to implied guarantees for merchantability and suitability for specific purposes Micsig is not responsible for errors or accidental or consequential damages caused by the provision use or use of this document or any information contained in it If a separate written agreement has been reached between Micsig and the user that contains wa...

Page 3: ...3 10 1 Product Introduction 5 2 Appearance 5 3 Specifications 6 4 Instructions 9 5 Maintenance 9 ...

Page 4: ...touch the measured conductor and sensor head during measurement Do not use in a humid environment Do not touch the instrument or the measured object with wet hands Please use this product within the range allowed by the end user Please use this product as required Please ground this product through the USB power cord ...

Page 5: ...ters via connector The maximum current can be measured to 100Apk 70Arms it has 2 models CP2100A and CP2100B CP2100A can measure bandwidth to DC 800KHz CP2100B can measure bandwidth to DC 2MHz 2 optional measuring ranges 10A and 100A Automatic and manual zero adjustment powered by USB no additional power supply making measurement more convenient Often used in motor drives industrial frequency inver...

Page 6: ...k 70 7Arms DC ACpk 200Apk pk 70 7Arms AC Maximum working voltage CAT III 300V CAT II 600V Maximum floating voltage CAT III 300V CAT II 600V Maximum conductor diameter 13mm Overload indication The buzzer sounds long and the button light flashes Supplied power DC 5V Probe head size 11 6 1 2 5cm Control box size 10 8 5 6 2 6cm Length 228cm Weight 290g Package weight 1000g Package dimensions 29 5 23 6...

Page 7: ...7 10 Maximum current VS Frequency curve Amplitude frequency characteristic curve CP2100A ...

Page 8: ...8 10 Amplitude frequency characteristic curve CP2100B DC signal linearity 0 01V A ...

Page 9: ...sition of the probe do not move it in a large range after the zero adjustment is completed 5 Open the jaws to clamp the conductor under test according to the direction indicated by the clamp head Note If the measured current flows in the opposite direction to the clamp head the output will be negative 6 Adjust the oscilloscope to get the best waveform Note When the current exceeds the range the bu...

Page 10: ...10 10 Shenzhen Micsig Instruments Co Ltd Tel 86 755 88600880 Email sales micsig com http www micsig com ...

Reviews: