Heat pump operational modes
Auto mode
- display shows a triangle symbol and a description ‘AUTO’. Heat pump automatically keeps the
requested water temperature. This means that heat pump automatically heats or cools when the
difference between water temperature and the requested water temperature is 2 degrees of Celsius.
The temperature difference of 2 degrees of Celsius is called Hysteresis. It is possible to change this
settings (please
see section 5.7 Setting of the operating parameters
, point 10).
Heating
- display shows a sun symbol. Heat pump only heats the water. This means that the heat
pump turns itself off after a requested water temperature is reached. Heat pump turns itself on again
when the water temperature decreases by 2 degrees of Celsius below the requested water
temperature. The temperature difference of 2 degrees of Celsius is called Hysteresis. It is possible to
change this settings (please
see section 5.7 Setting of the operating parameters
, point 10).
Cooling
- display shows a snow flake symbol. Heat pump turns itself off after a requested water
temperature is reached. Heat pump turns itself on again when the water temperature increases by 2
degrees of Celsius below the requested water temperature. The temperature difference of 2 degrees
of Celsius is called Hysteresis. It is possible to change this settings (please
see section 5.7 Setting of
the operating parameters
, point 10).
Recommendation:
Manufacturer recommends heat
pump regulation by AUTO-MODE.
Warning:
Manufacturer does not recommend changing of
hysteresis settings. It may be changed by an experienced user only.
5.4
Timer
It is possible to have your heat pump turned on and/or off automatically by timer function.
Automatic turning on
You can use this function when you would like your heat pump turned on after some time period. You
set the ‘Timer on’ function in STAND-BY mode (heat pump off and connected to the mains) by
pressing the ‘Clock’ button .
By pressing the buttons, you can set the number of hours after which the heat pump will
automatically turn itself on. The time setting range is 1-24 hours.
To confirm the settings, please no action for few seconds. You will see preset desired number of
hours, clock icon and icon ‘ON’ as shown on below picture.
Picture: Timer set on. Heat pump to
start in 6 hours.
Picture: Timer set on. Heat pump to
turn off in 6 hours.