Chapter 3 Specifications
Chapter 3 Specifications
3.1 Applicable regardless of the selected pressure sensor
Voltage supply
Battery: Li-SOCl2 cell with 1,2Ah
Housing
Material: POM / Stainless Steel (BLE Gauge / pressure sensor)
Weight: approx. 270g (incl. pressure sensor and 5 m cable)
Protection class: IP67
Dimensions (DL): 40 x 100mm / 21 x 74mm (BLE Gauge / pressure sensor)
Ex certification
II 3G Ex ic IIB T4 Gc
Operating temperature
-20...+50°C
Air humidity
15...90%rH non-condensing
Storage and transport
temperature
-20...+50°C
Temperature sensor
Measurement range: -20...+50°C
1)
Resolution: 0,05°C
Data type
Fill level [mm]: s16 (16Bit signed)
Temperature [0.05°C]: s16 (16Bit signed)
Data transmission
Bluetooth Low Energy:
Range: 20m (depending on the environmental conditions)
Device operating time
up to 5 years (depending on the measurement cycle)
1)
The compensation of the temperature-related influences on the fill level measurement only occurs in the range of
0...50°C .
3.2 BLE Gauge pressure sensor 0-1m 9W (300872)
Measurement range
0-1m
Resolution
1mm
Cable length
5m
suitable for
Fresh, waste and grey water
Measurement method
Piezoresistive pressure sensor
Rev. 02
9
Summary of Contents for 300871
Page 2: ......
Page 6: ......
Page 7: ...Chapter 2 Declaration of conformity Chapter 2 Declaration of conformity Rev 02 7 ...
Page 8: ...8 Rev 02 ...
Page 22: ......
Page 24: ......
Page 32: ......
Page 38: ......
Page 44: ......
Page 54: ......
Page 56: ......
Page 58: ......
Page 60: ......
Page 62: ......
Page 64: ......
Page 66: ......
Page 68: ......