background image

 

Microtel Series 100 Dialer

 

 

 
 

Installation and Operation Manual

 

 
 
 

P/N 310161 Rev B 

 

 
 

CAUTION:  Do not ship product with battery installed. 

 

 

 
 
 
 

Proprietary Notice:  This document and the subject matter hereto are the 
property of 

MICROTEL, Inc

. and shall not be reproduced or copied or 

used for the purpose of manufacturing or sale of apparatus, except by 
written permission of 

MICROTEL, Inc

 
 
 
 
 
 
 
 
 

 

  MICROTEL

 

206 West Judge Perez Drive 

Chalmette,  Louisiana   70043 

 

Phone:  

   

 504/276-0571 

Fax:         504/276-0574 

 

http://www.Microtel-Inc.Com 

e-mail:  [email protected]

 

Summary of Contents for 100 Dialer Series

Page 1: ...nt and the subject matter hereto are the property of MICROTEL Inc and shall not be reproduced or copied or used for the purpose of manufacturing or sale of apparatus except by written permission of MI...

Page 2: ...ii...

Page 3: ...rogramming 9 C Telephone Numbers 10 D Operational Parameters 10 1 Setting The Ring Count 10 2 Tone or Pulse Dial Selection 11 3 Message Repetitions 11 4 Intercall Delay 11 5 Access Code 11 III Operati...

Page 4: ...iv...

Page 5: ...qualified person to whom it can deliver a synthesized verbal message describing the alarm condition This message can be programmed by the user to consist of virtually any string of individual words in...

Page 6: ...rt damage claims to the shipping agent involved immediately Do not install damaged equipment All instructions given on any attached labels or tags should be followed Carefully inspect all packing mate...

Page 7: ...d approximately 5 feet above surface grade for proper microphone reception in both the speakerphone and intercom mode There are three access holes on the bottom of the unit The left side port is for p...

Page 8: ...s to the positive battery terminal and the black lead connects to the negative battery terminal Slide do not force the battery completely into the battery tray with the TERMINALS POINTED INTO THE SYST...

Page 9: ...d the unit is plugged in 120vac is contained within the system even though the internal STANDBY OPERATE switch may be turned off If the unit is to be installed in a location where large or high voltag...

Page 10: ...e FCC which places three restrictions on its use 1 The system cannot connect to a party line or a pay telephone line 2 The telephone company must be notified that an FCC registered device is being ins...

Page 11: ...annel s wire pair An eight position DIPswitch is provided to set the state of each channel to a normally open or normally closed configuration When the switch associated with a channel is in the OPEN...

Page 12: ...ed it may be powered up by switching the STANDBY OPERATE switch in the OPERATE position This switch is on the main printed circuit board inside the chassis and can be found by opening the front panel...

Page 13: ...number ready 2 Enter desired digits terminate the entire entry with a second depression of ENTER the station number is xx x To read this data READ 0 the station number is xx x Message Mode Entry of S...

Page 14: ...y channel The example below illustrates the telephone number programming procedure for telephone number 1 This programming operation may be performed for all telephone number positions which are to be...

Page 15: ...git number corresponding to the desired number of message repetitions the message count is xx Numbers less than 10 must be entered with a 0 as 01 05 etc To read this data READ the message count is xx...

Page 16: ...cess code at the proper time The following example illustrates how the access code may be programmed 1 ENTER access code ready 2 Enter four digits the access code is xxxx To read this data READ the ac...

Page 17: ...The RUN key will place the system in a run mode as indicated by the Run indicator If fault conditions exist the system will begin placing telephone calls if telephone numbers have been programmed int...

Page 18: ...number programming it inserts a short pause between digits in a telephone number When used with the ENTER key ENTER DELAY it sets the intercall delay time that is the time the system will wait after i...

Page 19: ...s This entire message will be repeated the number of times programmed If the entire message sequence is completed without an acknowledgement being returned over the telephone link the system will term...

Page 20: ...applicable ends with a key To remotely enter or alter a telephone number sequence 1 x where x is the telephone number slot to be programmed 1 11 telephone number 1 ready 2 Enter desired telephone num...

Page 21: ...ne number nine with the status message one time E TEST AND ADVANCED KEYSTROKE SEQUENCES A number of sequence commands are possible on the system front panel keyboard These are as follows ARCHIVE DATA...

Page 22: ...eight hours the battery is in need of replacement The battery installs at the top of the system in the battery tray provided as part of the interior chassis assembly It is necessary to remove power fr...

Page 23: ...interconnect FCC Registration Number D4J6M6 13598 AL E Dialing capacity 8 numbers 16 digits each maximum Dialing format Loop disconnect 10 pps nominal or tone user selectable Answer delay Programmabl...

Page 24: ...this warranty apply to equipment after the expiration of eighteen 18 months from date of shipping to the original purchaser whether or not the equipment is installed and which our examination shall d...

Page 25: ...H 043 ACCEPTED 011 NOT 044 ACCESS 012 NUMBER 045 ACKNOWLEDGE 013 OFF 046 ACTIVE 014 ON 047 ALARM 015 PHONE 048 AN 016 PLANT 049 AND 017 PLEASE 050 AUTOMATIC 018 POINT 051 BATTERY 019 POWER 052 CALL 02...

Page 26: ...RGE 205 DRYWELL 206 FLOODING 207 FLOW 208 GAS 209 HEADER 210 HUMIDITY 211 LEAK 212 LIFT 213 MOTOR 214 OVER 215 OVERLOAD 216 PRESSURE 217 PUMP 218 RESIDUAL 219 SHUTDOWN 220 SUCTION 221 SULFER 222 TEMPE...

Page 27: ...F POTENTIOMETER MAP 23...

Page 28: ...8 RESIDUE 269 DOOR 219 SALT 270 DOWN 220 SCRUBBER 271 DRYWELL 221 SECONDARY 272 DUMP 222 SENSOR 273 FEET 223 SEPARATOR 274 FILTER 224 SET 275 FLARE 225 SHUTDOWN 276 FLOOD 226 SITE 277 FLODDING 227 STA...

Reviews: