background image

Microtech User Manual  

 

2018 

 

Page 

6

 of 

6

 

 

4). The mug heater is identified as a consumable. You will need to change this for a a new one 

after doing transfer prints for roughly 700 cycles. If you use our Grade A mug heater, then 

you may change the mug heater after 2000 transfer cycles. 

5). If you are not able to solve the electrical parts problem, please kindly contact the supplier and 

get technical support. 

 

 

 

6.

 

Circuit Diagram 

 

 

Summary of Contents for MP-60

Page 1: ...Microtech User Manual 2018 Page 1 of 6 Digital Mug Heat Press Manual Model No Model No MP 60 Contents 1 Assembly Drawing 2 2 Technical Parameters 2 3 Operating Process 3 ...

Page 2: ...inting Methods 4 4 Recommendations 4 5 Maintenance 5 6 Circuit Diagram 6 1 Assembly Drawing 1 GY 04 Digital Controller 2 Power Socket 3 Power Switch 4 Handle toggle 5 Pressure Adjustment Screw 6 M5 Screw 7 Mug heater 8 Machine Feet 2 Technical Parameters MP 60 Technical Parameters Model No MP 60 ...

Page 3: ... on the machine via the power switch the temperature light will be ON The digital display will show the following on the LCD Press the OK button this will enable you to select a temperature reading C denotes Celsius Press arrows or to select or F denotes Fahrenheit according to your habits Press button to confirm your desired temperature reading the temp light will now display Select with arrows t...

Page 4: ...t to 20 and then press the OK button 5 seconds return to operation mode The temperature readings should now be accurate with the heat platen 3 Printing Methods Step 1 Make sure the cord is connected well to the wall socket Place the mug in the mug heater tape the transfer paper with the printed images facing down on the mug adjust the press to apply moderate pressure and power on P S please use he...

Page 5: ... heater will be required 3 The display screen shows 255 once you power on 1 Check whether the thermocouple connection is loose or not 2 If the thermocouple is connected well but still shows a temperature of 255 then it is faulty 4 The machine is heating during 0 180 but display number jumps to above 200 or 300 suddenly or the numbers on display jumps irregularly 1 Check whether the thermocouple of...

Page 6: ...ge this for a a new one after doing transfer prints for roughly 700 cycles If you use our Grade A mug heater then you may change the mug heater after 2000 transfer cycles 5 If you are not able to solve the electrical parts problem please kindly contact the supplier and get technical support 6 Circuit Diagram ...

Reviews: