Microtec M163 User Manual Download Page 1

 

MICROTEC S.r.l. 

Via Avris 3/A – 21032 CARAVATE (VA) ITALY 

C.F. – P.IVA 02356120127 – Reg. Imprese 24798/1997 VA 

Tel. +39 0332 601731 – Fax +39 0332 771777  

  

M163 UEGO Lambda Controller Bosch double 

 

USER MANUAL 

 

Warning!!!  To  display  the  correct  value  of  A/F,  before  attaching  a  probe  to  the 
connector  it  is  essential  to  set  in  M163  module  “the  identification  code  for 
calibration”  five  figures  reported  on  the  probe  itself.  This  parameters  is  a  unique 
code  associated  with  each  sensor  that  allows  M163  to  perform  compensation  and 
must  therefore  be  set  again  each  time  you  used  different  probes  or  the  probe  are 
connected  to  different  channels.  So  for  each  module  using  always  make  sure  the 
probes are connected to the correct channel. For details on how to settings the code 
refer to the “mode setting parameters”.  

 

Display modes 

 
The  M163  module  can  have  two  pages  to  display  data  acquired  in  each  of  which  are  expressed 
respectively  in  ratio  A/F  or  Lambda    (A/F  ratio  measured  in  relation  to  the  value  of  A/F 
stoichiometric). 
After a short message at startup, the system displays on the last page before the shutdown. 
It’s possible switch from one display mode to another by a simply press to the right button “<>”. 
 

How to set parameters 

 
The M163 module allows you to set for each channel the following parameters: 

-

 

IDs for calibration of the probes connected to the channels. 

-

 

IDs of CAN channels where data probes are transmitted. 

-

 

Transmission speed of  both CAN channels 

 

To change Calibration IDs or CAN IDs parameters, press left button  “

” until you see parameter to 

change. Pressing the right button “<>” you can entry in the mode of “edit”.  
In this mode you can change the single digit of the parameter to be amended by selecting the right 
key “<>”. The figure selected, which is marked with the symbol “^”, can be increased later by 
pressing left button “

”. Reached value  “F”,  with an additional pressure of the left button. “

”, you 

get the reset of the figure itself. 
The parameter is changed and saved when you selected the last digit, making a further press left 
“<>”. 
To change CAN Transmission Speed,  press left button  “

” until you see this parameter on display. 

Pressing the right button “<>” you can entry in the “edit” mode.  In this mode you can select the 
available CAN transmission speed  (1Mbit/sec or 500kbit/sec) by pressing, repeatedly,

 

left button 

” until you see the wished value.  The parameter is changed and saved by pressing left button 

“<>”. 
 

Reviews: