Microtec APDS-15 Manual Download Page 1

- 1 -

Pneumatic Double Location Shuttle

Heat Press Manual

APDS-15/20

CONTENTS

I. Assembly Drawing

-----------------------------------------------------------------------------------2

II. Technical Parameters

------------------------------------------------------------------------------2

III. Operation Process

-------------------------------------------------------------------------------3-4

IV. Maintenance

------------------------------------------------------------------------------------------5

V. Trouble Shooting For Transfer Print Quality

------------------------------------------------6

VI. Circuit Diagram

-------------------------------------------------------------------------------------6

VII. Explosion View

-------------------------------------------------------------------------------------7

CONTENTS

CONTENTS

I. As

I. As

Summary of Contents for APDS-15

Page 1: ...t Press Manual APDS 15 20 CONTENTS I Assembly Drawing 2 II Technical Parameters 2 III Operation Process 3 4 IV Maintenance 5 V Trouble Shooting For Transfer Print Quality 6 VI Circuit Diagram 6 VII Explosion View 7 CONTENTS CONTENTS I As I As ...

Page 2: ...40x60cm 4 Printable Articles Max Size 400 600mm 30mm 5 Voltage 220V 3 Phase 120V 1 Phase 6 Power 220V 1 8KW 110V 1 2KW 7 Recommend Setting Time 30 280s 180 210ć Time Range 0 999s Maximum Temp 225 C Heating Tube Power 1 8KW 1pc 8 Packaging size 1050 950 700mm 9 Gross Weight 97kg utton ƻ ƻ ƻ ƻ ƻStart Switch ƻ ƻAir P P e e ƻ ƻ ƻ ƻ ƻPneumatic Valve Pneumatic Valve ƻ ƻ ƻ CR ICR ICR II Technical Paramet...

Page 3: ...t with arrows the temperature according to different transfer material Normally 180к 200к 3 Set time required Press button after temperature setting and the time light is on Select with arrows the time according to different transfer material Press button after time setting the display shows the temperature starts to rise CD L shows the time counting down during your transfer Note There are two sm...

Page 4: ...or sublimation transfer paper 30 50 seconds pure cotton use for T shirt transfer paper 10 20 seconds 3 Aluminum Sheet transfer Set temperature 180ć Set time 45 seconds Emergency If any emergency happens please press the red emergency stop button After settled the emergency please turn the button clockwise and let it resume original status and the machine will also resume working status NOTE 1 Plea...

Page 5: ...eying electric to relay need to change controller 8 The setting temp and time becomes abnormal after exchange the heat platen Please reset the temp and time according the operation process manual 9 Other notice 1 In order to prolong the machine service life please add the lubrication oil regularly on the joints 2 In order to keep the heat platen s good transfer effect you need to protect the heat ...

Page 6: ...U Fuse 15A 25A SJ GY 04 Digital Controller HD Pneumatic Controller J1 Industrial Relay J2 Intermediate Relay Contacts L1 Indicator Light D Pneumatic Electromagnetic Valve EH1 EH2 Heating Pipe A B Thermocouple T1 T2 AC DC Transformer P Emergency Stop Button ...

Page 7: ... 1 14 Air Filter 1 15 Back Plate 4 16 Power Cord 1 17 Electronic Parts Bracket 1 18 Upper Cover Plate 1 19 Air Cylinder 1 20 Spindle with Base 1 21 Controller Cover 1 22 Electromagnet 2 23 Casting Polyurethane 2 24 Emergency Stop Button 2 25 GY 04 Digital Controller 1 26 Front Handle 1 27 Under Plate 1 rt Name t Name Qty Qty Machine Frame Machine Fram 2 2 2 Slide Rail Slide 3 Slide Rail Fixed Plat...