Operating Instructions Thread tapping units/ Accessoriesr 01/09, Software 4.9
©
01.1994-2016 microtap GmbH
40
DEPTH
RPM
M 4-5
0.10 mm 1000R 0150Ncm
Fig. 4-5 Operating menu
4.4.
Setting / changing the parameter
4.4.1. Operating
menu
Selectable functions
-
depth (mm or inch, see chapter “System setup”)
-
spindle speed min
-1
-
torque (Mz max in Ncm) / thread range
1. Press the selector key below the parameter you wish to set
2. Set the desired value by turning the alpha dial (rotary knob (6)).
3. To enter the selected value, press the selector key (1 - 3) below the appropriate
parameter again.
Now all selector keys are lightning. It is possible to cut a thread with these settings.
If you would like to form a thread or cut a left thread, you have to do like the
following.
NOTE
The machine will only operate in the operating menu.
4.4.2. Parameter
Menu
-
Press soft key (4) menu choice
-
Dial with the rotary knob (6) the desired function (the arrow shows the selected
menu).
-
To select the menu press the selector key (4)
PROGRAM
MOTOR SETUP
START SETUP
LUBRI.CYCLE
CHIP CLEARENCE
COUNTER
DATA MEMORY
PARAMETER RESET
OPTIONS
-
By pressing the soft key (7) BACK you can return from every menu to the
working menu. With soft key (4) you will get back to parameter menu.
-
If you get back from the parameter menu to the working menu, the settings for
start and program will be shown.