background image

 

 

 

 

 

microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach 

 +49 9681 91960-0, 

 +49 9681 91960-10, [email protected], www.microsyst.de 

 

 
 
 
 
 

migan ModbusTCP

 

Large Format Numeric LED Display with ModbusTCP Interface

 

 

 
 
 
 
 
 

User manual 

 
 
 
 
 

 

 

 
 
 

Summary of Contents for migan ModbusTCP

Page 1: ...emelectronic GmbH Am Gewerbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de migan ModbusTCP Large Format Numeric LED Display with ModbusTCP Interfa...

Page 2: ...dex 1 GENERAL 3 2 SYSTEM OVERVIEW 3 3 TECHNICAL DATA 4 3 1 Device Configuration 5 3 2 Connector Pin Assignments 6 3 3 Start Up 7 3 4 Modbus Configuration 8 4 CONTROLLING 9 4 1 Display Output 9 4 2 Res...

Page 3: ...w microsyst de 1 General This 7 segment displays are designed for professional use Depending on the type of device they are suitable for indoor or outdoor use The modular design allows for cost effect...

Page 4: ...1 40 Number of lines Standard 1 line multiple lines on request Display colour Standard red other colours on request Operating voltage 230 VAC 50 Hz 110 VAC 60 Hz or 24 VDC 20 View Single to four sided...

Page 5: ...f lines ________ Number of digits per line ________ Display colour Red Green Yellow White Blue View single sided double sided _____ sided Operating voltage 230 VAC 50 Hz 110 VAC 60 Hz 24 VDC Protectio...

Page 6: ...werbepark 11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 3 2 Connector Pin Assignments Please see inside labelling of the mating plugs for pin assignme...

Page 7: ...microsyst de www microsyst de Modbus TCP system interface Modbus Config RS232 3 3 Start Up After power up the display shows following Segment test first 2 digits of the baud rate parity data bits A di...

Page 8: ...n the area SUPPORT Anybus Communi cator Modbus TCP Serial Gateway Connect the display with a RS232 null modem cable pins 2 3 3 2 5 5 to a PC Laptop Start the software Close the window Konfiguration au...

Page 9: ...te Number of following bytes from ADR to CHK Device address Number of following bytes from O1 to CHK Options 00H FFH 08H n 01H 06H n Bit 7 report software version Bit 6 0 Statically display the last r...

Page 10: ...68 32767 6 101 signed LONG 2147483648 2147483647 11 110 ASCII representation 40 111 reserved at value representation right aligned display at ASCII representation left aligned display O3 O4 Decimal po...

Page 11: ...5 standard 55H fixed value or LOW byte of the sum of the bytes ADR to Dn Controlling devices with multiple display areas e g 2 lines The partition from O2 Dn is used repeatedly according to the number...

Page 12: ...02H Bit 7 Event digital input 4 Bit 6 Event digital input 3 Bit 5 Event digital input 2 Bit 4 Event digital input 1 Bit 3 Status digital input 4 Bit 2 Status digital input 3 Bit 1 Status digital input...

Page 13: ...11 92670 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 5 Appendix 5 1 Displayable Characters The data bytes are ASCII coded Lower Higher 0 1 2 3 4 5 6 7 0 Bla...

Page 14: ...no supply power steady green device operational flashing green module has not been configured flashing red recoverable fault steady red internal error flashing green red self test LED 2 Network Statu...

Page 15: ...flashing green frame is received or transmitted LED 5 Subnet Status RS485 State Description steady off power off flashing green initializing and not running steady green running steady red stopped su...

Page 16: ...response frame with response frame 4 Protocol Classic Protokoll Universal DIP2 is ignored 8 bits fixed 5 fixed value 55H instead of checksum only with protocol Universal use checksum only with protoco...

Page 17: ...vailable Direct exposure to light sources or direct sun rays reduces the reading quality Turn the device off for cleaning Protect the device from excessive moisture strong vibrations direct sun exposu...

Page 18: ...that the above men tioned product meets the requirements of the following standard Die bereinstimmung des bezeichneten Produk tes mit den Vorschriften der angewandten Richt linie n wird nachgewiesen...

Page 19: ...sible defects have to be indicated immediately after their perception too Generally defects and their symptoms must be described as accurately as possible in order to allow for reproducibility and eli...

Page 20: ...70 Windischeschenbach 49 9681 91960 0 49 9681 91960 10 info microsyst de www microsyst de 5 7 Versions Overview Version Date Remarks Description 1 00 1 10 1 20 1 30 23 11 15 25 01 16 27 04 16 20 11 17...

Reviews: