DOC 4380A
4380A O & M Manual
48
098-00723-000
– Jul 2017 Revision 4.0
SyncSystem 4380A O&M Manual
4380A>unlog ftp waas9a
[OK] 2015-08-07T20:56:19Z
4380A>settings gps_logging:ftp
[compression] true
[enable] true
[file_count] 100
[filename]
[digits] 3
[prefix] user
[suffix] nov
[type] timestamp
[interval] 15
[log_selection]
[bestposa] ontime 7200
[ionutca] ontime 7200
[rangea] ontime 60
[rawalma] onchanged
[rawephema] onchanged
[rxhwlevelsa] ontime 60
[waas9a] onchanged
[OK] 2015-08-07T20:56:49Z
Once the desired changes are made save the set up using the
save_logs ftp
command.
4380A>save_logs ftp
[OK] 2010-05-25T19:07:37Z
Note:
If you do not save the setup the system will come back up with the factory defaults when the system
is rebooted, restarted, or power cycled and any changes that were made will not be retained. Users can also
save these settings to a different configuration file if desired by adding the filename to the
save_logs ftp
command.
3.6.2 Real Time Data Logging
For this purpose, Port 1135 may be configured to provide real-time gps log output. Which logs are output
will be specific to the application but users may request any of the ASCII logs specified in the user manual
for the Novatel OEM6 receiver
To set up the real time data logging users will need to follow the steps outlined below to set up the type of
data to be logged and then turn the logging on. Users can also verify the data logging configuration
settings.
A.
Telnet into the command port (1700).
B.
Use the
log rt <novalog>
command to set up they data type to be sent over the data port. The
novalog
text on the command line specifies which data type to forward over this port. Some
examples are provided below.
4380A>log rt timea ontime 1
ionutca onchanged
// log IONO & UTC data
rawalma onchanged
// log almanac on startup
rangea ontime 60
// L1/L2 observations @ 60 seconds
ionutca ontime 7200
// log IONO & UTC data every 2 hours
rawephema onchanged
// log broadcast ephemerides
waas9a onchanged
// log WAAS data
C.
If needed, turn the real time logging on using the
log_enable rt
command.
4380A>log_enable rt 1
[OK] 2015-08-08T13:55:49Z
D.
You can verify the real time log settings using the
settings gps_logging:rt
command.
4380A>settings gps_logging:rt
[enable] true