![Microsemi SyncServer S600 User Manual Download Page 147](http://html1.mh-extra.com/html/microsemi/syncserver-s600/syncserver-s600_user-manual_1788481147.webp)
098-00720-000 Revision B – April, 2016
SyncServer 600 Series User’s Guide
145
Chapter 6 Provisioning
Provisioning Input References
Use the following methods to provision the GNSS port state and GNSS parameters
for the SyncServer S6x0.
Provisioning IRIG Inputs on Timing I/O Module
IRIG inputs are supported on Port J1 of the Timing I/O module with the SyncServer
S650.
Table 6-6. Enable GNSS Port and Set GNSS Parameters
Method
Steps
Notes
Web Interface
Timing >Input Control
1. Select radio button for External Input
Sources.
2. Click the GNSS check box.
3. Click the
Apply
button.
4.
Enable GNSS Port.
References > GNSS
1. Enter Elevation Mask value.
2. Use drop-down box to select Mode of
“Survey” or “Position Hold”.
3. Enter Latitude value if “Position Hold”
mode.Use drop-down box to select North
or South.
4. Enter Longitude value if “Position Hold”
mode. Use drop-down box to select East
or West.
5. Enter Altitude value if “Position Hold”
mode. Use drop-down box to select
dimensions.
6. Enter Cable Delay value.
7. Click the
Apply
button.
Set GNSS
parameters.
CLI
n/a
Front Panel
n/a
Note:
A Flex Port Option license is required for full configurability of
all BNC connectors on the Timing I/O module.