Installation Guide
CAUTION: DHCP Not Available
If the user selects DHCP, the SyncServer tries to reach a DHCP server for approximately 90
seconds before stopping. Please do not disconnect the power during this time.
ATTENTION : Si l'utilisateur choisit
DHCP,
le SyncServer essaye d'atteindre un serveur de
DHCP pendant approximativement 90 secondes avant de s'arrêter. Veuillez ne pas enlever
le courrant pendant ce temps.
LoggingintotheWebInterface
1. Get the LAN1 IP address by pressing the
STATUS
button repeatedly until the
LAN1
STATUS
screen is visible on the display.
2. Using Internet Explorer, enter the IP address as a URL. This displays the
Login
page.
3. At the SyncServer Login page, log in. The username is
admin
and password is
sym-
metricom
.
Note: When entering the IP address as a URL, leave off any leading zeroes in the IP
address. For example, instead of 192.168.047.025, enter 192.168.47.25.
Usingthe1stSetupWizard
Select the
WIZARDS
button and complete the
1st Setup
wizard.
1. Configure the SyncServer using
WIZARDS - 1st Setup
. Select the following options:
n
"Configure Password Recovery" (Ask the IT department for the IP address of the
SMTP server).
n
"Send test mail when finished"
n
"Set Local Time Zone"
Note: Reconfiguring LAN1 in the
1st Setup
wizard erases the previous network settings for all
Ethernet ports.
Also see
WIZARDS - 1st Setup
(on page 99).
Configuringthe Network Ports
Configure the remaining network ports using
NETWORK - Ethernet
.
Microsemi Recommends:
n
Using static IP addresses. (See explanation below.)
n
Using
Allowed Access
to protect the network ports from unauthorized IP addresses or
address ranges.
Explanation: NTP associations and authentication may rely on static network addresses. If a
DHCP server assigns a new address to a network port that has DHCP enabled, the asso-
ciations and authentication may stop working.
Also see
NETWORK - Ethernet
(on page 32).
997-01520-02 Rev. F1
..........................................................................
Page 149