7.2 Download Unit Configuration
Download unit configuration is very similar to upload unit configuration (see previous section):
1. Configure the TFTP Server as explained in Upload Unit Configuration.
2. Open a Telnet session with the unit (see Upload Unit Configuration), but this time select Download
configuration file from TFTP Server.
Figure 7-3: Download Unit Configuration
3. Type the TFTP Server IPv4/IPv6 address, file name (for example param.txt), and press Enter to
download the unit configuration file from the TFTP Server root folder to the unit itself.
Upon completion the unit will reset its internal Network Management module leaving PoE power
unchanged. Network traffic involving the PoE devices may be interrupted for a few seconds during the
time the Network Management Module re-initializes itself with the new configuration values.
NOTE:
1. Although the configuration file is text-based, please don't try to change it manually.
Such changes will be rejected (please see the message below).
2. For offline configuration changes please contact tech support at