Safety Information 

 

Important Safety Information 

  Installation and removal of the PoE  Midspan must be 

carried out only by qualified personnel.  

  Only an isolated AC/DC power source should be used 

to power up the POE Midspan. 

  The external power supply for the equipment will be a 

listed,  direct  plug  in power unit, marked Class 2, or 
listed ITE power  supply, marked LPS, which has 
suitably rated output voltage and current. 

 

DC

 Power Inlet: 

 

The power connector  supplied with the PoE Midspan 
(included in the package)  has 2 terminals;  '+'  (POS) 
and '-' (NEG) (See Figure 2).  

 

The power inlet  cables  (not included in the package) 
must be rated for current capacity of 2  Amperes 
(Stranded

 

tinned copper 16 AWG for each terminal).  

 

Before connecting power inlet cables to the connector 
terminals verify that the power source is off. 

 

After inserting a cable inlet to the connector terminals, 
tightly fasten all 4 connector screws (See Figure 2). 

 

This clause is optional: 
For improved EMI performance,  connect chassis 
ground connection to "Earth/Ground"  connection at 
the working area. 

 There is no safety hazard when the chassis  ground 
connection is not connected to the "Earth/Ground". 

 

 The PoE Midspan "

DATA IN

" and "

DATA & POWER OUT

ports are shielded RJ45 data sockets. They cannot be used 
to connect telephone wiring. Only RJ45 data connectors  
can be connected to these sockets.  

The 

DC

  power source  should  be  situated  near the PoE 

Midspan and easily accessible. To  disconnect the power 
from the PoE Midspan, disconnect the 

DC

 power cord from 

either the 

DC

 power source or from the PoE Midspan power 

connector.  

The PoE Midspan “

DATA IN

” and “

DATA & POWER OUT

” 

interfaces are qualified as SELV (Safety Extra-Low Voltage) 
circuits according to IEC 60950-1. These interfaces can be 
connected only to SELV interfaces of other equipment. 

 
WARNINGS: 

 

Before connecting the PoE Midspan to its power source, 
read the installation instructions. 

 

Whenever connecting the PoE Midspan to its power source, 
follow basic electricity safety measures. 

 

A voltage mismatch can cause equipment damage and may 
pose a fire hazard. If the voltage indicated on the label is 
different from the power outlet voltage, do not connect the 
PoE Midspan to this power outlet. 

 

Take extra care  when connecting the power inlet 
terminals, so that  '+’  (POS)  and  '-'  (NEG)  terminals are 
connected to the proper polarity. 

Mounting Instructions 

Perform the following instructions: 

1. 

Install two screws in the wall or shelf as shown in Figure 1. 

 

Figure 1: PoE Midspan mounting instructions

 

2. 

Align the PD-9501G/48VDC mounting slots to capture the surface 
screws. 

 

Recycling and Disposal 

Disposal instructions for old product: The WEEE (Waste Electrical & 
Electronic Equipment) national environmental initiatives has been put   
place to ensure that products are recycled using the best available 
treatment, recovery and recycling techniques so that human health  
and environmental protection considerations receive maximum  
attention. This product is designed and manufactured with high  
quality materials and components, which can be recycled and  
reused.  
Do not dispose your old product in a general house hold waste bin. 
Inform yourself about your local separate collection system for  
electrical and electronic products, marked by this symbol: 

 

Use one of the following disposal options : 
1. Dispose of the complete product (including its cables, plugs and 

accessories) in a WEEE designated collection facility. 

2. If you purchase a replacement product, hand your complete old  
product over to the retailer. He should accept it as required by the  
national WEEE legislation. 

 

 Microsemi Corp. 

 

Microsemi name & logo are registered trademarks of Microsemi 

corp.  

 

802.3at is a trademark of IEEE. 

Ordering information:  

  Product Name:

 Microsemi 9501G/48VDC 

  Part Number:

 PD-9501G/48VDC 

  Description:

 1-Port 802.3at 4-Pairs Gigabit PoE Midspan,  

48VDC input 

 

Document P/N  PD-9501G-48VDC_UG Rev. C00

 

 

 

 

 

 

 
 
Microsemi 9501G/48VDC

 

1B

User Guide 

 

2B

1-Port 802.3at

TM

 4-Pairs Gigabit 

PoE Midspan, 48VDC input. 

It is Microsemi’s policy to improve its products as new technology, 
components, software, and firmware become available. Microsemi 
therefore, reserves the right to change specifications without prior 
notice.

 

 

 

 

 

 

 

 

 

 

 

Notice 

Technical Support 

If you encounter problems when installing or using this product, 
please consult the Microsemi website at: 
http://www.microsemi.com

 

 

          For technical support, call: +972-9-775-5123 

          In the USA: 1-877-480-2323 

 

    Email: [email protected] 

 

 
 

 

 

Reviews: