3-48
Quadrus Verifier User’s Manual
ISO/IEC 15415 Verification by Serial Command
Multi-Capture Verification Report
After the final rotation and trigger, the Verifier will output the
ISO/IEC 15415 Multi-Capture
Verification Report
, shown below.
The
ISO/IEC 15415 Multi-Capture
parameters are the same as those for
ISO/IEC 15415
Single Capture
, but multi-capture results are determined only after the symbol is read at
five 72° intervals throughout a full 360° rotation. The overall symbol grade is based on an
arithmetic mean of the results from the five reads.