Chapter 3
3-8
MS-810 Industrial Scanner User’s Manual
3–Ser
ial
Conf
ig.
used for these data fields. (Refer to Table A-4, “ASCII Table with Control Characters,” on
page A-10 for more information.)
Preamble
Format: <
Kd
status,preamble character(s)>
Example: To enable Preamble with just one character, an FF (form feed), send
<Kd1,^L>
.
Postamble
Format: <
Ke
status,postamble character(s)>
Example: To disable Postamble, send
<Ke0>
.
LRC
Format: <
Kc
status>
Example: To enable LRC, send
<Kc1>
.
Table 3-2 Protocol Commands
Protocol Command
(Mnemonic displayed on
Microscan menu)
Control Characters
(Entered in menu or
serial command)
Effect of Command
RES
^D
Reset
REQ
^E
Request
EOT
^D
Reset
STX
^B
Start of Text
ETX
^C
End of Text
ACK
^F
Acknowledge
NAK
^U
Negative Acknowledge
status:
0 = Disabled
1 = Enabled
preamble
c
haracter(s):
Enter one or two preamble characters except a null
(00H). Default is
^M
.
status:
0 = Disabled
1 = Enabled
postamble character(s):
Enter one or two postamble characters except a
null (00H). Default characters are
^M^J
.
status:
0 = Disabled
1 = Enabled
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...