Chapter 2
2-28
MS-810 Industrial Scanner User’s Manual
2–Menu Conf
ig
.
Interleaved 2 of 5
Default:
Disabled
Options: Disabled,
Enabled
Because I 2 of 5 is a continuous code, it is prone to substitution errors. Hence, a code
length must be defined and a bar code label containing an even number of digits must
be used. It is also recommended that a Modulus 10 check digit be used to ensure the
best possible data integrity.
Check Digit
Default:
Disabled
Options:
Disabled, Enabled
I 2 of 5 uses a Modulus 10 check digit.
Check Digit Output
Default:
Disabled
Options:
Disabled, Enabled
When enabled, the check digit character is sent along with the label data. When dis-
abled, label data is sent without the check digit.
Code Length #1
Default:
10
Options:
0 to 64, even. If you enter an odd number the scanner will use the next
lower number.
With I 2 of 5, two code lengths can be defined. When using only one label length in an
application, we recommend setting Code Length #2 to 0 to ensure data integrity. If a
check digit is used, it must be included in the code length count.
Code Length #2
Default:
6
Options:
0 to 64, even. (If you enter an odd number the scanner will use the next
lower number.)
If using a second label, you may also specify a zero or any even code length from 2 to
30. If not using a second label, set Code Length #2 to 0 to ensure data integrity.
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...