Chapter 2
2-12
MS-810 Industrial Scanner User’s Manual
2–Menu Conf
ig
.
Protocol Menu
Protocols define the sequence and format in which information is transferred between devices.
Figure 2-3 Protocol
Default
Clicking the
DEFAULT
button will reset all parameters on the current menu to
defaults. This does not take effect until it is saved to the scanner with the
SEND/NO
SAVE
or
SEND/SAVE
buttons.
Selected Protocol
Default:
Point-to-Point
Options: Point-to-Point, Point-to-Point with XON/XOFF, Point-to-Point with RTS/CTS,
Point-to-Point with RTS/CTS & XON/XOFF, Polling Mode D, Multidrop, User
Defined, User Defined Multidrop Protocol
Point-to-Point
Has no address and sends data to the host (RS-232) whenever it is available and
without any request or handshake from the host.
Point-to-Point with RTS/CTS (Request-to-Send/Clear-to-Send)
Used only with RS-232. This is a simple handshaking protocol that allows a device to
initiate data transfers to the host with an RTS (request-to-send) transmission. The
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...