Code Types Commands
MS-610 Scanner User’s Manual
3-11
3–Ser
ial
Conf
ig.
I
2 of 5
Format:
<
Kr
status,check digit status,check digit output status,code length
#1,code length #2>
Example:
To set Fixed Code Length #1 to 8 and Fixed Code Length #2 to 4,
enter
<Kr,,,8,4>
or
<Kr1,0,0,8,4>
.
UPC/EAN
Format:
<
Ks
UPC status,EAN status,supplementals status,separator
status,separator character>
/
Example:
To change Supplementals to Required, and change Separator
Character to a dash (–), enter
<Ks1,1,2,1,–>
or
<Ks,,2,1,–>
.
Code 128
Format:
<
Kt
status,fixed code
length status,code length>
Example:
To enable Code 128, enable Fixed Code Length, and set Code
Length to 9, enter
<Kt1,1,9>
.
status:
0 = Disabled
1 = Enabled
check digit status:
0 = Disabled
1 = Enabled
check digit output status:
0 = Disabled
1 = Enabled
code length #1:
Zero or any even
number from 2 to 30.
Default is
10
.
code length #2:
Zero or any even
number from 2 to 30.
Default is
6
.
UPC status:
0 = Disabled
1 = Enabled
EAN status:
0 = Disabled
1 = Enabled
(UPC must also be
enabled)
supplementals status:
0 = Disabled
1 = Enabled
2 = Required
separator status:
0 = Disabled
1 = Enabled
separator character:
Any ASCII character
(except NUL). Default is
a comma (
,
).
status:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Any number from 1 to 31.
Default is
10
.