Chapter 3
Serial Configuration
3-10
MS-610 Scanner User’s Manual
3–Ser
ial
Conf
ig.
Code Types Commands
Narrow Margins
Format:
<
Ko
status>
Example:
To enable Narrow Margins, enter
<Ko1>
.
Code 39
Format:
<
Kp
status,check digit status,check digit
output status,large intercharacter gap,fixed code
length status,code length>
Example:
To set Fixed Code Length to 30, enter
<Kp,,,,1,30>
or
<Kp1,0,0,0,1,30>
.
Codabar
Format:
<
Kq
status,start & stop match status,start & stop output
status,large intercharacter gap,fixed code length status,code length>
Example:
To set Fixed Code Length to 9, enter
<Kq,,,,1,9>
or
<Kq1,1,1,0,1,9>
.
status:
0 = Disabled
1 = Enabled
status:
0 = Disabled
1 = Enabled
check digit status:
0 = Disabled
1 = Enabled
check digit output
status:
0 = Disabled
1 = Enabled
large intercharacter gap:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Any number from 1 to
31. Default is
10
.
status:
0 = Disabled
1 = Enabled
start & stop match status:
0 = Disabled
1 = Enabled
start & stop output
status:
0 = Disabled
1 = Enabled
large inter-character gap:
0 = Disabled
1 = Enabled
fixed code length status:
0 = Disabled
1 = Enabled
code length:
Any number from 1
to 31. Default is
10
.