Communications Commands
MS-610 Scanner User’s Manual
3-7
3–Ser
ial
Conf
ig.
Postamble
Format:
<
Ke
status,postamble character(s)>
Example:
To enable Postamble, enter
<Ke1>
.
Response Timeout
Format:
<
KA
timeout setting>
Example:
To change Response Timeout to 30 ms, enter
<KA30>
.
LRC
Format:
<
Kc
status>
Example:
To enable LRC, enter
<Kc1>
.
Intercharacter Delay
Format:
<
KB
time interval>
Example:
To change Inter-character Delay to 30 ms, enter
<KB30>
.
Host Port
Format:
<
Ka
baud rate,parity,stop bits,data bits>
Example:
To c
hange Host Port Baud Rate to 2400, enter
<Ka2>
.
status:
0 = Disabled
1 = Enabled
postamble character(s):
Enter one or two postamble characters except a null
(00H). Default characters are
^M^J
.
timeout setting:
Any number from 0 to 6500 (a zero creates an indefinite wait). Default is
0
.
status:
0 = Disabled
1 = Enabled
time interval (between characters in milliseconds):
Any number from 0 to 255. Default is
0
.
baud rate:
0 = 600
3 = 4800
6 = 300
1200
4 = 9600
2 = 2400
5 = 19.2K
parity:
0 = None
1 = Even
2 = Odd
stop bits:
0 = One
1 = Two
data bits:
0 = Seven
1 = Eight