
Code Types Menu
MS-610 Scanner User’s Manual
2-23
2–Menu C
on
fig.
Interleaved 2 of 5
Status
Default:
Disabled
Options: Disabled,
Enabled
Because
I
2 of 5 is a continuous code, it is prone to substitution errors.
Hence, a code length must be defined and a bar code label containing an
even number of digits must be used. It is also recommended that a Modulus
10 check digit be used to ensure the best possible data integrity.
Check Digit
Default:
Disabled
Options: Disabled, Enabled
I
2 of 5 uses a Modulus 10 check digit.
Check Digit Output
Default:
Disabled
Options: Disabled, Enabled
When enabled, the check digit character is sent along with the label data.
When disabled, label data is sent without the check digit.
Code Length #1
Default:
10
Options: 0 to 30, even. If you enter an odd number the scanner will use the
next lower number.
With
I
2 of 5, two code lengths can be defined. When using only one label
length in an application, we recommend setting Code Length #2 to 0 to
ensure data integrity. If a check digit is used, it must be included in the code
length count.
Code Length #2
Default: 6
Options: 0 to 30, even. If you enter an odd number the scanner will use the
next lower number.
If using a second label, you may also specify a zero or any even code
length from 2 to 30. If not using a second label, set Code Length #2 to 0 to
ensure data integrity.