A-2
MS-5000 Multidrop Concentrator User’s Manual
Appe
ndices
Appendix A — MS-5000 Specifications
Physical Characteristics:
Length: 6.2 in. (157.5 mm)
Width: 6.61 in. (167.9 mm)
Height: 1.36 in. (34.5 mm)
Weight: 16 oz. (453 grams)
Figure A-1 MS-5000 Dimensions
0.5"(12.7)
6/32 threads
(6.35mm)
4 places
Inches (mm)
Rear
Front
CAUTION: The 6-32 mounting screws
should not extend more than 0.12 in.
(3 mm) into the mounting holes.
1.85"
(46.99)
5.6" (142.24)
2.5"
(63.5)
6.2"
(157.48)
5
.8"
(
147
.32
)
3.
8"
(9
6.5
2)
Measurements in inches (millimeters)
Front
5.2" (132.08)
4.5" (114.30)
5.8" (147.32)
0.030" (7.62)
1.
0"
(2
5.4
)
0.160" (4.06) DIA
(4 places)
Communications Settings
Host Port Communications
Interfaces: RS-232, RS-422, RS-485
ACSII Character Format:
7
or 8 Data Bits
Stop Bits:
1
or 2
Baud Rates: 600, 1200, 2400, 4800,
9600
, 19.2K, 38.4K
Selectable Parity: Odd,
Even
, or None
Protocols:
Point-to-Point
, Polling Mode D, Multidrop, User
Defined, and User Defined Multidrop
LAN Port Communications
Interface: 4-wire, RS-485, RS-422
ACSII Character Format:
7
or 8 Data Bits
Stop Bits:
1
or 2
Baud Rates: 600, 1200, 2400, 4800,
9600
, 19.2K, 38.4K
I/O Port: 6-pin, 6-wire modular
Protocols: Multidrop, User Defined Multidrop
(up to 50 devices per concentrator)
Auxiliary (Monitor) Port Communications
Interface: RS-232
ACSII Character Format:
7
or 8 Data Bits
Stop Bits:
1
or 2
Baud Rates: 2400, 4800,
9600
, 19.2K, 38.4K
I/O Port: 9-pin, D-subminiature plug
Protocol: Point-to-Point
Electrical Characteristics
+12 VDC @ 40 mA max., 20 mV p-p max. allowed ripple
–12 VDC @ 40 mA max., 20 mV p-p max. allowed ripple
+5 VDC @ 300 mA max., 200 mV p-p max. allowed ripple
Operating Environment
Operating Temperature: 32° to 113°F (0° to 45°C)
Storage Temperature: –58° to 158°F (-50° to 70°C)
Humidity: 0% to 95% (non-condensing)
Status Lights
Three LEDs (light emitting diodes) on the front panel of the concen-
trator serve as visual indicators to verify that it is operating correctly.
IND 1: Flashes green each time data is sent to the host.
IND 2: Illuminates red whenever the concentrator is in a ready
state or is polling the connected devices. When this light goes off,
a data-buffer-full condition exists and the concentrator is no longer
polling the devices.
PWR: Illuminates red when the power switch is in the ON position.
Summary of Contents for MS-5000
Page 1: ...MS 5000 Multidrop Concentrator User s Manual P N 83 005000 REV J...
Page 8: ...viii MS 5000 Multidrop Concentrator User s Manual...
Page 52: ...Chapter 3 Menu Configuration 3 18 MS 5000 Multidrop Concentrator User s Manual 3 Serial Config...
Page 66: ...Chapter 4 Serial Commands 4 14 MS 5000 Multidrop Concentrator User s Manual 4 Operations...
Page 90: ...A 14 MS 5000 Multidrop Concentrator User s Manual Appendices...