Chapter 4
Serial Commands
4-4
MS-5000 Multidrop Concentrator User’s Manual
4–
O
per
ati
ons.
Host Port
Baud Rate, Parity, Stop Bits, Data Bits
Set communications parameters for the host port.
Format: 51
<
Ka
baud rate,parity,stop bits,data bits>
CR
Example:
To c
hange Host Port Baud Rate to 2400, enter
<Ka2>
.
Host RS-422
Toggle between RS-232 and RS-422.
Format: 51<
Kb
status
>CR
Example:
To enable RS-422, enter
51<Kb1>CR
.
Turnaround Timeout
Time the concentrator will wait for a response from the host.
Format: 51<
Kh
timeout
>CR
Example:
To change the timeout to 30 ms, enter
51<Kh30>CR
.
Intercharacter Timeout
Time the concentrator will wait between inidvidual characters from the host.
Format: 51<
Ki
timeout
>CR
Example:
To change the timeout to 30 ms, enter
51<Ki30>CR
.
Poll Response Timeout
Time the concentrator will wait when in polled mode to the host.
Format: 51<
Ks
poll response
timeout
>CR
Example:
To change the poll response timeout to 20 ms, enter
51<Ks20>CR
.
baud rate:
0 = 600
4 = 9600
1 = 1200 5 = 19.2K
2 = 2400 6 = 300
3 = 4800
parity:
0 = None
1 = Even
2 = Odd
stop bits:
0 = One
1 = Two
data bits:
0 = Seven
1 = Eight
0 = Disable
1 = Enable
Any number from 1 to 250, Default is
15 ms
.
Any number from 1 to 250, Default is
15 ms
.
Any number from 1 to 250, Default is
15 ms
.
Summary of Contents for MS-5000
Page 1: ...MS 5000 Multidrop Concentrator User s Manual P N 83 005000 REV J...
Page 8: ...viii MS 5000 Multidrop Concentrator User s Manual...
Page 52: ...Chapter 3 Menu Configuration 3 18 MS 5000 Multidrop Concentrator User s Manual 3 Serial Config...
Page 66: ...Chapter 4 Serial Commands 4 14 MS 5000 Multidrop Concentrator User s Manual 4 Operations...
Page 90: ...A 14 MS 5000 Multidrop Concentrator User s Manual Appendices...