Step 2 — Connect the System
MS-4Xi – Ethernet
• Connect the M12 (power and I/O) end of the imager’s cable to the
power supply (
2
).
• Connect the RJ45 (Ethernet) end of the imager’s cable to the host.
• Plug in the power supply to apply power to the imager.
MS-4X – RS-232 / RS-422
• Connect the imager (
1
) to the IB-131/IC-332 interface (
4
) and (
3
).
• Connect the communication cable (
7
) to the host, and to the host
port on the IB-131.
• Connect the object detector (
6
) to the IB-131.
• Connect the power supply (
5
) to the IB-131.
• Plug in the power supply to apply power to the imager.
MS-4X – USB
• Plug the imager’s USB cable into the host’s USB port. The imager
is powered by the USB connection.
Caution:
Be sure that all cables are connected
BEFORE
applying power
to the system. Always power down
BEFORE
disconnecting any cables.
Step 1 — Check Hardware
Item
Description
Part Number
1
MS-4X, MS-4Xi
FIS-1004-1X10G
2
Power Supply, M12 12-pin Socket, 1.3 m
(Screw-On) (MS-4Xi only)
97-000003-03
3
IC-332 Adapter
FIS-0001-0035G
4
IB-131 Interface Box
99-000018-01
5
Power Supply (90-264 VAC, 24VDC,
USA/Euro plug)
97-100004-15
6
Object Detector
99-000017-01
7
Communication Cable
61-300026-03
Hardware Required
MS-4X
MS-4Xi
1
2
1
4
3
7
5
6
Quick Start Guide
MS-4X Imager Series
P/N 83-110444 Rev B
Step 3 — Position Imager
• Place the imager and test symbol in a location with as little ambient light
as possible.
• Position the imager at a distance from the symbol that matches the factory
pre-set focal distance. If your imager is pre-set at 4” (Standard Density),
position the parting line 4” from the symbol. If your imager is pre-set at 3”
(Low Density), position the parting line 3” from the symbol.
• Tip the imager relative to the symbol to avoid glare from specular reflection.
Avoid excessive skew or pitch. Maximum skew is
±30°
; maximum pitch is
±30°
).
• Symbols can be rotated (tilted) at any angle; however, for best results
symbols should be aligned with the FOV (field of view). In the case of linear
symbols, aligning the bars in the direction of their movement (“ladder”
orientation) will minimize the chances of blurring and No Reads.
Imager / Symbol Positioning
Step 4 — Install ESP
ESP Software can be found on the Microscan Tools Drive that is packaged
with the imager.
1. Follow the prompts to install ESP from the Tools Drive.
2. Click on the ESP icon to run the program.
Note:
ESP can also be installed from the
Download Center
at
www.microscan.com
.
Refer to the user manual for detailed information about using ESP to
configure the imager.
Minimum System Requirements
• 233 MHz Pentium PC
• Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit)
• Internet Explorer 6.0 or higher
• 128 MB RAM or greater
• 160 MB free disk space
• 800 x 600 256 color display (1024 x 768 32-bit color recommended)
Step 5 — Select Model
When you start
ESP
, this menu will appear:
1. Click the button showing the imager used in your application.
2. Click
OK
.
Note:
You can also simply double-click the button showing your
imager to make your selection.
3. Click
Yes
when this dialog appears:
Note:
If you need to select another model later, click the
Switch
Model
button near the top of the screen or use
Model > New
Model
in the menu toolbar.