Step 2 — Connect the System
Connecting by RS-232 / RS-422 / RS-485
•
Connect the imager (
1
) to the IB-131/IC-332 interface (
2
) and (
3
).
•
Connect the host cable (
6
) to the host and to the host port on the IB-131 (
3
).
•
Connect the object detector (
5
) to the IB-131 (
3
).
•
Connect the power supply (
4
) to the IB-131 (
3
).
•
Apply power to the imager.
Hardware Configuration
Caution:
Be sure that all cables are connected
BEFORE
applying power
to the system. Always power down
BEFORE
disconnecting any cables.
Scanner
Networ
k
Host
1
2
3
6
4
5
Step 1 — Check Hardware
Item
Description
Part Number
1
EZ Match Imager
FIS-0004-11XXG
2
IC-332 Adapter
FIS-0001-0035G
3
IB-131 Interface Box
99-400018-01
4
Power Supply
97-100004-15 (90-264 VAC, 24 VDC)
5
Object Detector
99-000017-01
6
Host Cable
61-300026-01
Scanner
Networ
k
Host
1
2
3
6
4
5
Caution:
Be sure that all cables are connected
BEFORE
applying power
to the system. Always power down
BEFORE
disconnecting any cables.
Hardware Required
Quick Start Guide
EZ Match Imager
P/N 83-210051 Rev B
Step 3 — Position Imager
•
Place the imager in an area with as little ambient light as possible.
•
Place a black surface behind the area in which test tubes, caps, or symbols
will be inspected by the imager.
The black background provides the contrast necessary for the imager to
detect the presence or absence of objects in its field of view.
•
Position the imager at a focal distance between
2
and
6
inches from a
sample tube, cap, or symbol.
•
Position the imager relative to the object to avoid the glare of direct
(specular) reflection.
Important:
Avoid excessive skew or pitch. Maximum
skew is
±30°
; maximum pitch is
±30°
.
•
Objects can be rotated at any angle; however, for best results, objects
should be aligned with the FOV (field of view).
Note:
For accuracy of testing and performance, Microscan recommends
using a mounting arm adapter kit. Contact your Microscan sales manager
for details about mounting arm adapter kits and other accessories.
2
4
6
8
10
ml
EZ Match Imager and Object in Field of View
Place a black
background
behind the area
where tubes,
caps, or symbols
will be inspected
by the imager.
This provides the
contrast necessary
for the imager to
detect the presence
or absence of
objects in the field
of view.
Step 4 — Install ESP
ESP (Easy Setup Program)
is Microscan’s proprietary setup and testing
software. It is
not
meant to be a tool for a real-time production environment; the
purpose of
ESP
is to provide a quick and easy way to set up and configure your
imager. With your imager connected to a host computer (Windows™ Vista, XP,
or 2000), you can use
ESP
for configuration and imager testing.
If installing from the Microscan Tools CD:
1. Insert the Microscan Tools CD in your computer’s CD drive.
2. Select
ESP Software
from the navigation bar at the left of the screen.
3. Click on
ESP Software
under the
Current Version
heading.
4. Click the
Run
button and follow the prompts in the
ESP
Setup Wizard.
If downloading from the web:
1. Go to the Download Center at
2. Create a new member account or, if you are already a member, enter
your user name and password.
3. Navigate to the “Microscan Software” section of the Download Center
(near the top of the page)
.
4. Click on the link showing the latest version of
ESP
. Extract the
ESP
installation files to a location of your choice on the host computer.
Note
where your ESP.exe file is stored on your hard drive.
5. At the end of the installation process, the following icon will appear on
your desktop:
6. Click the
ESP
icon to start the program.
ESP System Requirements
•
166 MHz Pentium processor (recommended)
•
Windows Vista, XP, or 2000 operating system
•
Internet Explorer 5.0 or higher
•
64 MB minimum RAM
•
40 MB minimum disk space
•
800 x 600 pixel minimum 256 color display
Step 5 — Select Model
The following menu will appear when you start ESP:
1. Click the button showing the EZ Match Imager.
2. Click
OK
.
Note:
You can also double-click the EZ Match button to make your
selection.
3. Click
Yes
when this dialog appears:
Important:
An EZ Match
Imager must be connected
to the host computer for its
corresponding icon (shown
at left) to appear on the
model menu.
The icon will always be
present in subsequent
ESP
sessions, even when the EZ
Match unit is not physically
connected.
Note:
If you need to select another model later, click the
Switch
Model
button near the top of the screen or use
Model > New
Model
in the menu toolbar.