when the battery requests charging current
from the charger.
•
Yellow LED is lit. Charging time will vary
depending on the type of battery and the
degree of discharge.
•
Green LED is lit when the battery is fully
charged. The battery charger change to
maintenance charging.
NOTE
The green LED will not light immediately if a fully
charged battery is connected. This time can vary
between 0 and 2 hours.
Stopping a charge cycle
Turn off the battery charger by disconnecting the
mains cable.
Maintenance and
troubleshooting
The checks below are recommended to be car-
ried out during troubleshooting and maintenance.
WARNING
High voltage!
Only qualified personnel should install, use,
maintain and service this product.
Disconnect the battery and power supply before
maintenance, servicing or dismantling.
WARNING
High voltage!
Do not use the battery charger if it is damaged.
Disconnect the mains immediately.
Do not touch damaged parts, uninsulated battery
terminals, connectors, or other live electrical
parts.
Contact service personnel.
Safety shut-off
Charging is terminated if:
•
Voltage and current exceed the maximum set
value.
•
The battery is disconnected without the
battery charger being stopped.
Charging is temporarily stopped or reduced when:
•
The battery charger temperature exceeds
charger limits.
Checking error messages
If the battery charger’s built-in self-testing function
detects a fault, this is indicated via the status
LED’s on the front panel. Please make a note of
any faults and send for authorised service
personnel.
Checks
1. Check the cables and connectors for
damages.
2. Check that the battery is free from defects, in
good condition and is the correct type for the
battery charger.
3. Check that the battery is properly connected
and that the battery fuse, if any, is not broken.
4. Check that the mains voltage is right and that
there are no blown fuses.
Technical data
Operational ambient temperature: −25 to 50 °C
(−13 to 122 °F)
(1)
Storage temperature: −40 to 85 °C (−40 to
185 °F)
Mains voltage: See data label
(2)
.
Output voltage: 24 V
Battery types: Li-ion
Recommended max battery capacity: 180 Ah
Efficiency: >90% at full load.
Ingress protection: IP40
Approvals: CE and/or UL. See data label
(2)
.
1) 30 to 50 °C (86 to 122 °F) with derated charging power.
2) Located on the battery charger.
Recycling
The battery charger is recycled as metal and
electronics scrap. Local regulations apply and
must be followed.
Contact information
Micropower Sweden AB
Idavägen 1, SE-352 46 Växjö, Sweden
Phone: +46 (0)470-727400
e-mail:
ENGLISH
7
Summary of Contents for LION 9
Page 2: ......
Page 99: ...www micropower group com 日本語 99 ...
Page 180: ...Figures 180 ...
Page 181: ...Approvals Declaration of Conformity 181 ...
Page 182: ...182 ...
Page 183: ...183 ...
Page 184: ......
Page 185: ......