6. INSTALLATION
The design features of the ECOTECH filter mean it is conceived for use on board the machine,
installed in the immediate vicinity of the utilities and connected via rigid or flexible raceways to the
collection systems which the machine tools are equipped with.
On the top, the filter is fitted with a grid through which the filtered air exits, therefore, for outdoor
installations, it is advisable to protect the filter using a canopy in order to keep the article safe from
infiltrations of rain.
7. ADJUSTMENTS
7.1 System
To adjust the unit flow rate, intervene on the throttle shutter (optional), mounted on the raceways
using the respective knob. The opportunity to adjust the flow rate allows better execution of the
work, ensuring a longer working life for the various filtering baffles and less power absorption by
the fan with consequent energy saving.
8. MAINTENANCE
Do not perform maintenance while the machine is operating or connected to the electrical energy source. During these phases,
remember to disconnect the plug and, if necessary, padlock the control to prevent unwanted start-ups.
When cleaning the filters, do not use flammable liquids.
The filter has been designed not to require particular regular maintenance. It is nevertheless
advisable to:
Check the condition of the electrical power cables periodically;