Microlife NC 200 Manual Download Page 7

7

NC 200

EN

13. Guarantee

This device is covered by a 

5 year guarantee

 from the date of 

purchase. During this guarantee period, at our discretion, Microlife 

will repair or replace the defective product free of charge.

Opening or altering the device invalidates the guarantee.

The following items are excluded from the guarantee:

Transport costs and risks of transport.

Damage caused by incorrect application or non-compliance 

with the instructions for use.

Damage caused by leaking batteries.

Damage caused by accident or misuse.

Packaging/storage material and instructions for use.

Regular checks and maintenance (calibration).

Accessories and wearing parts: Batteries, Probe cover (optional).

Should guarantee service be required, please contact the dealer 

from where the product was purchased, or your local Microlife 

service. You may contact your local Microlife service through our 

website: 

www.microlife.com/support

Compensation is limited to the value of the product. The guarantee 

will be granted if the complete product is returned with the original 

invoice. Repair or replacement within guarantee does not prolong 

or renew the guarantee period. The legal claims and rights of 

consumers are not limited by this guarantee. 

14. Technical Specifications

This device complies with the requirements of the Medical Device 

Directive 93/42/EEC.

Technical alterations reserved.

According to the Medical Product User Act a biennial technical 

inspection is recommended for professional users. Please 

observe the applicable disposal regulations.

Type:

Non Contact Thermometer NC 200

Measurement 

range:

Body mode: 34.0 - 43 °C / 93.2 - 109.4 °F

Object mode: 0.1 - 99.9 °C / 32.2 - 211.8 °F

Resolution:

0.1 °C / °F

Measurement 

accuracy 

(Laboratory):

Body mode:

±0.2 °C, 35.0 

 42.0 °C / ±0.4 °F, 95.0 

 107.6 °F 

±0.3 °C, 34.0 

 34.9 °C and 42.1



 43.0 °C /

±0.5 °F, 93.2



 94.8 °F and 107.8



 109.4 °F

Object mode:

±1.0 °C, 0.1 ~ 99.9 °C / ±2 °F, 32.2 ~ 211.8 °F

Display:

L

iquid 

C

rystal 

D

isplay, 4 digits plus special icons

Acoustic:

The unit is turned ON and ready for the measure-

ment: 1 short beep.

Complete the measurement: 1 long beep (1 sec.) if 

the reading is less than 37.5 °C / 99.5 °F, 10 short 

«beep» sounds, if the reading is equal to or greater 

than 37.5 °C / 99.5 °F.

System error or malfunction: 3 short «bi» sounds.

Memory:

30 readings recall in the memory mode with a 

record of both time and date.

Backlight:

The display light will be GREEN for 1 second, 

when the unit is turned ON.

The display light will be GREEN for 5 seconds, 

when a measurement is completed with a reading 

less than 37.5 °C / 99.5 °F.

The display light will be RED for 5 seconds, when 

a measurement is completed with a reading equal 

to or higher than 37.5 °C / 99.5 °F.

Operating 

conditions:

Body mode: 15 - 40.0 °C / 59 - 104.0 °F

Object mode: 5 - 40.0 °C / 41 - 104.0 °F

15 - 95 % relative maximum humidity

Storage 

conditions:

-25 - +55 °C / -13 - +131 °F

15 - 95 % relative maximum humidity

Automatic 

Switch-off:

Approx. 1 minute after last measurement has been 

taken.

Battery:

2 x 1.5 V alkaline batteries; size AAA

Battery 

lifetime:

approx. 2000 measurements 

(using new batteries)

Dimensions:

156.7 x 43 x 47 mm

Weight:

91.5 g (with batteries), 68.5 g (w/o batteries)

IP Class:

IP22

Reference to 

standards:

ASTM E1965; IEC 60601-1; IEC 60601-1-2 (EMC); 

IEC 60601-1-11

Expected 

service life:

5 years or 12000 measurements

Summary of Contents for NC 200

Page 1: ...enstrasse139 9443Widnau Switzerland 139 9443 ONBOElectronic Shenzhen Co Ltd No 138 HuashengRoad LangkouCommunity DalangStreet Longhua District Shenzhen China No 138 41717277000 41717277001 admin micro...

Page 2: ...ty information Microlife Non Contact Thermometer NC 200 EN 1 Measuring sensor 2 Tracking light 3 Self indicator light 4 Display 5 M button memory 6 MODE button 7 START IO button 8 Battery compartment...

Page 3: ...0 1 99 9 C 32 2 211 8 F meaning the unit can be used to measure body temperature or it also has a feature allowing it to be used to measure surface temperature of the following examples Milk surface t...

Page 4: ...or an ambulance is advised if needed 3 How this Thermometer measures Temperature This thermometer measures infrared energy radiated from the forehead as well as objects This energy is collected throug...

Page 5: ...display 8 For the next measurement remove the thermometer from the forehead and wait until the C F icon is flashing Follow steps 4 5 above 9 Press and hold the START IO button 7 for 3 seconds to turn...

Page 6: ...yed Pressing and releasing the M button 5 after the last 30 readings have been recalled will resume the above sequence from reading 1 10 Error Messages Measured temperature too high AR Displays H when...

Page 7: ...al regulations Type Non Contact Thermometer NC 200 Measurement range Body mode 34 0 43 C 93 2 109 4 F Object mode 0 1 99 9 C 32 2 211 8 F Resolution 0 1 C F Measurement accuracy Laboratory Body mode 0...

Page 8: ...d pressure monitors as well as services can be found at www microlife com Date of production first six digitsof the serial number of the device First and second digit the year of production third and...

Page 9: ...9 NC 200 EN...

Page 10: ...10 BF Microlife Microlife 1 Microlife NC 200 RU 1 2 3 4 5 M 6 MODE 7 START IO 8 9 AT AK AL AM AN AO AP AQ 30 AR AS BT BK BL BM BN BO BP BQ BR BS SN N...

Page 11: ...11 NC 200 RU 2 3 4 5 6 7 8 9 30 10 11 12 13 14 15 www microlife ua 1 5 0 1 99 9 C 32 2 211 8 F y o 30 10 37 5 C 2...

Page 12: ...12 15 3 3 m 3 4 9 START IO 7 1 AT C F BR 3 3 2 1 AK 4 C F C F AN 5 1 BO 5 MODE 6 2 5 MODE 6 3 4 START IO 7...

Page 13: ...BO 1 MODE 6 3 BP 2 5 BP START IO 7 10 AT 6 1 START IO 7 4 1 2 AL MODE 6 AM MODE 7 BS 1 START IO 7 4 1 2 C F 2 AT 3 4 5 5 1 5 3 2 1 3 6 3 7 8 C F 4 5 9 START IO 7 3 60 1 START IO 7 4 1 2 MODE 6 3 C F 2...

Page 14: ...97 9 100 4 F Microlife NC 200 35 4 37 4 C 95 7 99 3 F 8 C F MODE 6 3 MODE C F AO C F M 5 START IO 7 10 AT 9 30 30 AP M 5 M 1 AQ M 5 1 M 5 30 1 10 AR H 43 C 109 4 F 99 9 C 211 8 F AS L 34 C 93 2 F 0 1...

Page 15: ...rolife www microlife com support 14 NC 200 34 0 43 C 93 2 109 4 F 0 1 99 9 C 32 2 211 8 F 0 1 C F 0 2 C 35 0 42 0 C 0 4 F 95 0 107 6 F 0 3 C 34 0 34 9 C 42 1 43 0 C 0 5 F 93 2 94 8 F 107 8 109 4 F 1 0...

Page 16: ...www microlife ua 30 1 37 5 C 99 5 F 5 37 5 C 99 5 F 5 15 40 0 C 59 104 0 F 5 40 0 C 41 104 0 F 25 55 C 13 131 F 15 95 1 2 x 1 5V AAA 2000 156 7 x 43 x 47 mm 91 5 68 5 IP22 ASTM E1965 IEC 60601 1 IEC 6...

Page 17: ...17 NC 200 RU...

Page 18: ...18 BF Microlife o Microlife Microlife NC 200 UA 1 2 3 4 5 M 6 MODE 7 STAR IO 8 9 AT AK AL P AM P AN AO AP AQ 30 AR AS BT BK BL BM BN BO BP BQ BR BS e CE SN N...

Page 19: ...19 NC 200 UA 1 2 3 4 5 6 7 8 9 30 10 11 12 13 14 15 www microlife ua 1 5 sm 0 1 99 9 C 32 2 211 8 F 30...

Page 20: ...20 10 37 5 C 2 15 3 3 m 3 4 9 START IO 7 1 AT C F BR 3 3 2 1 AK 4 C F C F...

Page 21: ...ODE 6 3 4 START IO 7 20 AT 7 START IO 7 30 MODE 6 8 BO 1 MODE 6 3 BP 2 M 5 BP START IO 7 10 AT 6 1 START IO 7 4 1 2 AL MODE 6 AM MODE 7 BS 1 START IO 7 4 1 2 C F 2 AT 3 4 5 sm 5 1 5 sm 3 2 1 3 6 3 7 8...

Page 22: ...C F 4 5 7 START IO 7 3 60 30 10 37 5 C 6 1 2 3 34 7 37 3 C 94 5 99 1 F O 35 5 37 5 C 95 9 99 5 F P 36 6 38 0 C 97 9 100 4 F Microlife NC 200 35 4 37 4 C 95 7 99 3 F 8 C F MODE 6 3 MODE C F AO C i F M...

Page 23: ...1 10 AR H 43 C 109 4 F 99 9 C 211 8 F AS L 34 C 93 2 F 0 1 C 32 2 F BT AH 40 C 104 0 F BK AL 15 C 59 F 5 0 C 41 0 F BL Er 0 Er 6 Er 2 1 5 sm BM BN 11 70 y 12 2 1 5 CR2032 BN BQ 13 5 Microlife Microli...

Page 24: ...7 6 F 0 3 C 34 0 34 9 C 42 1 43 0 C 0 5 F 93 2 94 8 F 107 8 109 4 F P 1 0 C 0 100 0 C 2 F 32 0 212 F 4 1 1 1 37 5 C 99 5 F 10 37 5 C 99 5 F 3 30 1 37 5 C 99 5 F 5 37 5 C 99 5 F 5 15 40 0 C 59 104 0 F...

Page 25: ...25 NC 200 UA...

Reviews: