5
Microlife BP A7 Touch BT
EN
reached, the device will automatically pump some more air into
the cuff.
6. During the measurement, the pulse indicator
BR
flashes in the
display.
7. The result, comprising the systolic
AP
and the diastolic
AQ
blood
pressure and the pulse rate
AR
are displayed. Note also the
explanations on further display symbols in this booklet.
8. When the device has finished measuring, remove the cuff.
9. Switch off the device. (The monitor does switch off automati
-
cally after approx. 1 min.).
How not to store a reading
As soon as the reading is displayed press and hold the START/
STOP button
1
until
«M»
AO
is flashing. Confirm to delete the
reading by pressing the M-button
AO
.
How do I evaluate my blood pressure
The LED traffic light indicator on the left-hand side of the display
AP
indicates within which range the measured blood pressure lies.
The value is either within the optimum (green), elevated (yellow) or
high (red) range. The classification corresponds to the following
ranges defined by international guidelines (ESH, ESC, JSH). Data
in mmHg.
The higher value is the one that determines the evaluation.
Example: a blood pressure value of
140/80
mmHg or a value of
130/90
mmHg indicates «blood pressure too high».
5. Data memory
This device automatically stores up to
99
measurement values for
each of the 2 users and guest mode.
Viewing the stored values
Switch the lock switch
3
to «unlock» position. Select either user
1 or 2 with the user indicator
BM
. Press the M-button
AO
briefly. The
display shows an average value.
Pressing the M-button again displays the previous value. Pressing
the M-button repeatedly enables you to move from one stored
value to another.
Memory full
Clearing all values
Make sure the correct user is activated.
1. Firstly unlock the device
3
, then select either 1 or 2 with the
user indicator
BM
.
2. Hold down the M-button
AO
until
«CL»
appears and then
release the button.
3. Press the M-button while
«CL»
is flashing to permanently clear
all values of the selected user.
AF detection is only activated in AFIB/MAM mode.
You can stop the measurement at any time by pressing the
ON/OFF button or open the cuff (e.g. if you feel uneasy or
an unpleasant pressure sensation).
This monitor is specially tested for use in pregnancy and
pre-eclampsia. When you detect unusual high readings in
pregnancy, you should measure after a short while again
(eg. 1 hour). If the reading is still too high, consult your
doctor or gynecologist.
In pregnancy the AFIB symbol can be ignored.
«CL»
is displayed when the reading is deleted from the
memory successfully.
Range
Systolic Diastolic Recommendation
1. blood pressure
too high
≥135
≥85
Seek medical
advice
2. blood pressure
elevated
130 - 134 80 - 84
Self-check
3. blood pressure
normal
<130
<80
Self-check
Pay attention that the maximum memory capacity of
99
memories per user is not exceeded.
When the
99
memory
is full, the oldest value is automatically overwritten with
the
100th value.
Values should be evaluated by a doctor
before the memory capacity is reached – otherwise data will
be lost.
Cancel deletion:
press START/STOP button
AN
while
«CL»
is flashing.
Individual values cannot be cleared.
Range
Systolic Diastolic Recommendation
Summary of Contents for BPA7 Touch BT
Page 117: ...115 Microlife BP A7 Touch BT FA ...