SYSTEM SETTINGS TAB
System Power:
Displays the source voltage for local PORT A and PORT B separately. If the jumpers are configured for
INT/SRC, the voltage displayed will be approximately .3V-0.7V less than the power supply voltage. If
either jumper is set for SNK, the voltage displayed for particular port is 0V.
Acceptable voltage range is +11 to 24V.
If the voltage is less that 11V, UNDERVOLTAGE will be displayed.
If the voltage is more than 24V, OVERVOLTAGE will be displayed.
Enable sleep mode
:
If Station Master Deluxe is connected to a
microKEYER II it will follow the MK II sleep
status.
NOTE:
Sleep control has no function if Station Master
Deluxe is not used with an MKII.
Enable button beep:
When checked, SMD will generate short beeps on each button press.
Enable alarm beep:
When checked, SMD will generate three short beeps in an alarm condition.
IMPORTANT:
The settings on this tab are valid only when Station Master Deluxe is connected to
micro
HAM
Router. In order for SMD to function in stand alone mode, the settings must be saved to Station Master
Deluxe as power-up defaults using “Device | Store as Power-Up Settings.”
33