MANUAL CONTROL
Normally when the display is set to #/MAN, the module will
display the index # for the module's output vector table and
will cycles the display for each configured unit. Different units
are indicated by decimal points in the same manner as they
are shown in USER display. The Left decimal point shows the
first unit, middle the second, right the third, and middle and
second fourth unit.
For troubleshooting purposes it is possible to control outputs
of the module manually. To switch module into the manual
mode, cycle the SET button until #/MAN LED is lit then press
and hold SET button until #/MAN LED starts flashing. When
#/MAN is flashing the module is in manual mode and
automatically generates INHIBIT signal to the SMD preventing
usage of the module by any SMD.
In manual control mode, all outputs are exclusively controlled
individually by the front panel buttons. The display will show
output number 001 to 006 (010). Use the
34
buttons to
select the output and the
n
button to toggle output state.
Relay modules have no internal jumpers or adjustments; the
case does not need to be opened for setup or operation.
100
uLINK RELAY10 output wiring