background image

 
 
 
 
 
 

REI2 

 

 

Summary of Contents for REI2

Page 1: ...REI2...

Page 2: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 2 of 64 User manual...

Page 3: ...RONIZATION OF REI2 S INTERNAL CLOCK 18 6 1 Synchronization 18 6 2 Modifying synchronization value 18 6 3 Synchronization verify 18 6 4 Signal 18 7 BATTERY RECHARGE 20 7 1 Discharge recharge 20 7 2 Imm...

Page 4: ...nputs 44 17 1 10 LinkPod 44 17 1 11 Start 45 17 2 Sports homologization 45 17 3 Technical conformity certificates 45 18 GUARANTEES AND RESPONSIBILITIES 46 1 INTRODUCTION TO LINKGATE 48 2 LINKGATE ENCO...

Page 5: ...nc005 54 3 12 3 Decoder e DecRadio 54 4 LICENCES 55 5 FIGURES 56 5 1 Linkgate EncRadio 56 5 2 Linkgate DecRadio 58 5 3 DecRadio 58 5 4 Taking the speed 59 1 INTRODUCTION TO LINKPOD 61 1 1 Information...

Page 6: ...ets 31 Fig 8 Example of connection using both the banana jack sockets and the DIN sockets 32 Fig 9 Diagram for N O line 33 Fig 10 Diagram for N C line 33 Fig 11 Diagram for N O line with 1 impulse onl...

Page 7: ...an operational autonomy of about 20 hours and 21 days when off but with maintenance of synchronization 8 lines a second thermal graphic printer 240 by 64 point graphic display with lighting feature H...

Page 8: ...Version 1 07 9 Page 8 of 64 2 A look at REI2 2 1 Top Fig 1 Overview 1 Printer compartment 2 Graphic display 3 Line keyboard 4 Main keyboard 1 3 2 4 LCK LCK LAP STA AUX STO F5 ALT ENT ESC 0 F4 F3 F2 F1...

Page 9: ...79_002_E Version 1 07 9 Page 9 of 64 2 1 1 Printer compartment 1 2 4 3 5 6 Fig 2 Printer compartment 1 Slot for spindle 2 Paper compartment 3 Thermal head 4 Roller 5 Head block lever 6 Reset button fo...

Page 10: ...iate Rearm on the lines selected by the user with activation signal led 3 LCK Software block on the Stop line with activation signal led 4 ARM Immediate Rearm of the Stop line with activation signal l...

Page 11: ...back 3 Light key activates the back lighting of the graphic display 4 ALT key modifies the functioning of the other keys 5 ENT key usually confirms what is done 6 ESC key usually allows you to quit wh...

Page 12: ...d snow temperature 4 Digital input output for connection to devices with digital command e g MicroSem signal light or unblocking devices 5 Input for LinkGate Decoder and DecRadio connection 6 Serial I...

Page 13: ...ide 1 Fig 6 Left side speacker connector 1 External speaker connector 2 5 Materials in the REI2 package REI2 is supplied togetherwith the following material The REI2 stopwatch A bag for transport Adap...

Page 14: ...ed are shown inside chevrons For example press F1 means the yellow key marked F1 while the options proposed by REI2 are indicated in bold type This symbol draws your attention to points about which yo...

Page 15: ...you will see 1 07 9 followed by 0 or 1 indicating the battery type 1 indicates longlife batteries while 0 indicates standard duration Note The request for synchronization does not appear if the inter...

Page 16: ...TA key SYNCHRONIZATION Input hour 09 30 00 0000 Input date 03 06 2003 START to synchronize SYNCHRONIZED menu As soon as the impulse has been received the message SYNCHRONIZED appears for a few moments...

Page 17: ...Press F5 to activate this function 2 Press F3 to activate this choice The presence or absence of particular choices depends on the function program activated It will often be necessary to insert nume...

Page 18: ...nization of REI2 to align it with other devices which cannot be resynchronized After establishing the gap in synchronization between the two devices for example with a stop in parallel insert its valu...

Page 19: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 19 of 64 The signal is generated by switching pin 6 of the I O digital port to level 0...

Page 20: ...tomatically as soon as a voltage level is restored To recharge the batteries connect the plug for recharging to any continuous current supply between 11 and 24 volts In the REI2 package a special adap...

Page 21: ...r manual Doc R2U_2_1079_002_E Version 1 07 9 Page 21 of 64 7 3 Interrupt With this function the discharge and recharge phases are interrupted REI2 returns to maintenance status until external power is...

Page 22: ...e regulation of the residual battery charge This operation should be repeated every 6 months to offset natural deterioration in the performance of the internal batteries First REI2 discharges the batt...

Page 23: ...inue appears and you must delete one of the stored races to be able to continue 9 2 Delete Retrieve stored race This option allows you to retrieve or delete a previously stored race from the list of r...

Page 24: ...y deletion Selecting this option allows you to delete all the data of all the stored races On the display the message ATTENTION All data and races will be irreversibly cancelled proceed Press F4 for Y...

Page 25: ...off the stopwatch completely with retention of all the data stored but the loss of synchronization Pressing the key F3 for STANDBY puts REI2 in a state of suspension everything is switched off except...

Page 26: ...5 days 11 1 Memory capacity REI2 has a 2 MB memory for storing events and the configurations of various races This memory is big enough to store about 65 000 events When the memory is full the message...

Page 27: ...the dedicated REI2 PC connecting cable Here are the steps you must follow Connect the PC serial output to the REI2 Computer A input Switch on REI2 by keeping the keys F1 F2 ed F3 simultaneously press...

Page 28: ...ks 13 2 DIN lines On the DIN connector the same 4 lines and the relative ground are available together with stabilised power supply for powering external devices such as cells It is therefore possible...

Page 29: ...utput has 1200 bps 8 bits of data 1 stop no parity Although a computer can be connected to this output to intercept data sent to the displayboards and to maintain compatibility with software already w...

Page 30: ...lied in the REI2 package should be connected to this connector REI2 accepts a voltage of between 9 and 24 volts on the input Keep in mind that with voltages between 9 and 11 volts the internal batteri...

Page 31: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 31 of 64 Fig 7 Example of connection using the banana jack sockets Photocell Gate Start line Stop line...

Page 32: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 32 of 64 Fig 8 Example of connection using both the banana jack sockets and the DIN sockets Photocell Gate Start line Lines...

Page 33: ...E Version 1 07 9 Page 33 of 64 Fig 9 Diagram for N O line Fig 10 Diagram for N C line T min 1 10 000s 2 8 volt 5 volt 2 2 volt 0 volt T min 1 1 000s 2 8 volt 5 volt 2 2 volt 0 volt T min 1 10 000s T m...

Page 34: ...Version 1 07 9 Page 34 of 64 Fig 11 Diagram for N O line with 1 impulse only 2 8 volt 5 volt 2 2 volt 0 volt T 1 10 000s 2 2v Valid impulse T 1 1 000s 2 8v T Too short line not reopened T 1 1 000s 2...

Page 35: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 35 of 64 Fig 12 Example of connection between two computers 9 pole female CANNON plug COMPUTER A COMPUTER B Computer...

Page 36: ...REI2 User manual Doc R2U_2_1079_002_E Version 1 07 9 Page 36 of 64 Fig 13 Example of connection of a MicroTab displayboard 9 figure alphanumeric MICROTAB displayboard Serial 1 Displayboard...

Page 37: ...79_002_E Version 1 07 9 Page 37 of 64 Fig 14 Example of connection of two or more MicroTab displayboards 9 figure alphanumeric MICROTAB displayboard Serial 1 Serial 2 Displayboard Serial 2 if required...

Page 38: ...roup starts C Simple stopwatch D Parallel Other A Show jumping B Swimming C PC ONLINE D Dual timer B Delete Recall stored race C Continue current race D Clear all memory Others A Battery recharge A Di...

Page 39: ...e is autonomy for about 150 time events To change the paper follow these instructions Open the printer compartment by turning the fastening screw in an anti clockwise direction Take out the finished r...

Page 40: ...he paper from the printer manually by releasing the head with the appropriate for this lever and carefully pulling it out with your hands When you have finished this operation reblock the head again w...

Page 41: ...is updated may be reduced and there may be a loss of measurement accuracy of 0 05 ppm C After a few minutes the inside of the device naturally warms up limiting such problems Temperatures above 50 C...

Page 42: ...I2 from the back The connection schemes are provided for documentation Microgate recommends the use of its own dedicated cables which have undergone the EU standards tests 6 pole DIN 45322 female pane...

Page 43: ...3 Digital I O 240 6 pole socket for connection of digital acquisition devices 1 Digital input output 0 0 5V configurable via software 2 Digital input output 1 0 5V configurable via software 3 Digital...

Page 44: ...0 6 pole socket standard signal RS 485 1 2 3 Serial output RS485 4 Serial output RS485 5 GND 6 17 1 9 Timing Inputs 240 6 pole socket signal at TTL level contacts not polarised 1 START 2 Regulated 5V...

Page 45: ...rtificates Technical conformity certificates are available from Microsoft Details of the certificates issued by Italy Germany France and Switzerland are given below Nation Authority Certificate Italy...

Page 46: ...rom the date of delivery Microgate cannot accept any responsibility for breakages of REI2 or other equipment due to incorrect connection of power sources or auxiliary devices including those produced...

Page 47: ...B LINKGATE SYSTEM...

Page 48: ...transmitter radio make the LinkGate Encoder the ideal instrument for training and competitions at every level The components of the LinkGate system are Type Power supply Radio Encoder Enc003 Trasmitt...

Page 49: ...his system ensures maximum reliability and precision 0 4 thousandths of a second the complete reception of a single set of data is all that is required to reconstruct the original time of the event 2...

Page 50: ...ering with one another For the REI2 stopwatch consult the individual program manuals 3 2 Selecting signal type LinkGate Encoder makes it possible to identify the type of impulse that is being transmit...

Page 51: ...he set of data will only be transmitted 4 times so you will have lower redundancy but with a substantial reduction of transmission time For normal use we advise you always to use long transmission swi...

Page 52: ...o an operational state On the other side from the keyboard there is a hole in the case By inserting a pointed instrument you will press a button which will reset it We suggest you keep the button down...

Page 53: ...g any impulses LinkGate Encoder will download the entire contents of the memory 256 times 256 speeds IMPORTANT During data downloading onto REI2 disconnect the LinkGate Decoder from the stopwatch Also...

Page 54: ...nd Encoder Enc005 modules are powered by internal NiMh batteries which can be recharged with the adaptors supplied They can be used without recharging for about 10 000 impulses or 8 hours in the displ...

Page 55: ...tend to use them In Italy with the exception of specific cases users of transceivers must have a licence DecRadio and EncRadio The DecRadio and EncRadio modules do not require a licence in Italy and t...

Page 56: ...A POSTERIORE VISTA LATO SINISTRO 1 SIGNAL button 2 SECOND FUNCTION button 3 Selector for redundancy of signal transmitted Long Short 4 On Off switch 5 REPEAT button 6 MODEM button 7 Rotating selector...

Page 57: ...TO INFERIORE VISTA LATO SUPERIORE 1 SIGNAL signal banana jack GREEN 2 Earth signal banana jack BLACK 3 SPEED signal banana jack RED 4 5 pole Nucletron connector for Radio connection and data download...

Page 58: ...nual Doc R2U_2_1079_002_E Version 1 07 9 Page 58 of 64 5 2 Linkgate DecRadio 5 3 DecRadio 1 2 3 1 BNC for external antenna connection 2 5 pole Nucletron connector for Radio output 3 Cover for access t...

Page 59: ...18 Taking the speed D EC R ADIO POLIFEMO E NC R ADIO BLACK PLUG IN BLACK SOCKET CAB048 or CAB050 POLIFEMO GREEN PLUG IN GREEN SOCKET GREEN PLUG IN RED SOCKET GREEN PLUG IN GREEN SOCKET BLACK PLUG IN B...

Page 60: ...C LINKPOD SYSTEM...

Page 61: ...d by any module in a very short time maximum150 ms Therefore also simultaneous events such as the simultaneous closing of all 80 contacts are acquired and reported to REI2 within 150 ms maintaining ma...

Page 62: ...ations and so can also be used at a swimming pool 1 5 Maintenance After being used at a swimming pool the Pods should be washed in running water and left to dry before they are put away to avoid damag...

Page 63: ...rogram version Chapter Page Editing description 1 03 Removal of introductory chapter to transmission protocol now inserted in the manual Transmission protocol 1 06 6 3 18 New function Synchronization...

Page 64: ...r Microrun MicroLink Flasher LinkPod LinkGate LinkGate encoder LinkGate decoder EncRadio DecRadio Polifemo MicroSem Sem are registered marks of Microgate s r l or of licensed users Microgate s r l res...