Figure 3-2. Xplained Nano Standard Pinout for UPDI
NC
UPDI
NC
NC
VREG
VUSB
GND
CLK OUT
CDC TX
CDC RX
VCC
GND
Micro USB Connector
mEDBG
Power disconnect
Status LED
3.4
Disconnecting mEDBG
The target device can be completely separated from the mEDBG, but this requires some small modifications to the
board using a soldering iron. By removing the resistors in the sections shown in the figure below, the mEDBG is
completely disconnected from the target controller. If desired to connect the mEDBG again, solder in 0Ω resistors or
solder in 100-mil headers on the header footprints and use wire-straps to connect the interfaces.
Figure 3-3. Kit Modifications
Power disconnect
mEDBG disconnect
ATtiny416 Xplained Nano
Xplained Nano
©
2019 Microchip Technology Inc.
User Guide
DS50002683B-page 8